background image

 7 

HUSKYTOOLS.COM

 

 

Please contact 1-888-43-HUSKY for further assistance.

Pre-Installation

PLANNING INSTALLATION

WARNING:

 Disconnect, tag, and lock out the power source 

before attempting to install or relocate the compressor.

IMPORTANT:

 This compressor is not intended for outdoor 

installation.

It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air temperature will not be more 
than 100°F. Provide a minimum clearance of 18 in. between the compressor fl ywheel or fan and the wall, and ensure clear access to the 
drain valve to facilitate condensate drainage. Do not locate the compressor air inlet near steam, paint spray, sandblast areas, or any other 
source of contamination.

TOOLS REQUIRED

Claw hammer

Safety goggles

Phillips 
screwdriver

Flat blade 
screwdriver

Measuring 
tape

Adjustable 
wrenches (2)

Ratchet, 
1/4 in. and 
9/16 in. socket

Pipe wrench

Hammer drill 
and masonry 
bit

Voltage meter

Work gloves

HARDWARE REQUIRED

NOTE:

 Hardware not shown to actual size.

Concrete wedge 
anchors

Vibration isolation 
set (3 metal plates 
and 6 rubber pads)

e

Strain relief

Summary of Contents for HS518102

Page 1: ...enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 80 GALLON STATIONARY AIR COMPRESSOR Questi...

Page 2: ...ntly hazardous situation which if not avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CA...

Page 3: ...he tank resulting in damage from rupture or explosion Always replace worn cracked or damaged tanks CAUTION See the compressor specification decal for maximum operating pressure Do not operate with pre...

Page 4: ...not recommended for use with this compressor Alterations and or modifications are a form of misuse which could result in a hazardous condition leading to possible personal injury or equipment damage...

Page 5: ...l and local electrical codes 1 Follow all local electrical and safety codes as well as in the United States the National Electrical Codes NEC and Occupational Safety and Health Act OSHA 2 Avoid body c...

Page 6: ...or expense that may result from any defect failure or malfunction of the manufacturer s product is not covered by this warranty Some states do not allow the exclusion or limitations of incidental or...

Page 7: ...inimum clearance of 18 in between the compressor flywheel or fan and the wall and ensure clear access to the drain valve to facilitate condensate drainage Do not locate the compressor air inlet near s...

Page 8: ...8 Pre Installation PACKAGE CONTENTS Part Description Quantity A Air Compressor Unit 1 B Air Filter Assembly 1 A B...

Page 9: ...ximum C Discharge Tube This tube carries compressed air from the pump to the check valve This tube becomes very hot during use To avoid the risk of severe burns never touch the discharge tube D Check...

Page 10: ...utlet Size 3 4 NPT Number of Cylinders 2 Oil Capacity approximately 2 quarts Voltage 230 240 Volts 22 Amps Length 27 in 60 Hz 1 Phase Width 35 in Air Delivery 90 psi 14 0 SCFM Height 70 in Air Deliver...

Page 11: ...to the drain valve to facilitate condensate drainage IMPORTANT It is extremely important to install the compressor in a clean well ventilated area where the surrounding air temperature will not be mo...

Page 12: ...onry bit Holes drilled must be at least as deep as the concrete wedge anchors being used 3 Inserting the mounting bolts Insert the mounting bolts into the drilled holes Place a washer on each bolt Thr...

Page 13: ...t For units that do not have a factory installed cord install permanent wiring from the electrical source to the pressure switch with a ground conductor connected to the grounding screw on the pressur...

Page 14: ...l 2 line terminal 3 ground screw 4 and ground line 5 3 Making the electrical connections Remove the ground screw 1 Install the strain relief on the pressure switch 2 Do not tighten the strain relief o...

Page 15: ...Place a flathead screwdriver into the raised notch and tap the screwdriver with a hammer until tight Tighten the strain relief screws 2 to hold the power cord securely 5 Reinstalling the pressure swit...

Page 16: ...ife of the unit you will clean or replace the filter as needed This air compressor unit can be installed as part of an air distribution system Any tube pipe or hose used in an air distribution system...

Page 17: ...ass on the pump to determine the oil level Add oil to the pump if the oil level is low 2 2 Starting up and breaking in the compressor WARNING Do not attach air tools to the open end of the hose until...

Page 18: ...or the drain valve may be damaged Drain the tank of moisture daily using the drain valve at the bottom of the tank IMPORTANT This condensation will cause water spots in a paint job especially when spr...

Page 19: ...llect in the pan Reinsert the oil drain plug Remove the oil fill plug 3 Pour new unused oil into the pump Do not overfill Reinsert the oil fill plug 3 into position Return power to the compressor for...

Page 20: ...pump The belt should be slack and easily removed Replace the belt Move the motor back to the original position to create belt tension Tighten the motor bolts 6 Aligning tensioning the belt Lay a strai...

Page 21: ...cate or perform any maintenance Operation Daily Weekly Monthly Every 3 Months Check Oil Level X Drain Tank X Check Air Filter X Check Safety Valve X Clean Unit X Check Belt Tension X Change Oil X IMPO...

Page 22: ...level and change the oil more frequently The piston pin bores are worn Remove the piston assemblies from the compressor and inspect for excess wear Replace the excessively worn piston pin or pistons a...

Page 23: ...restricted Clean or replace the air filter element The electrical connections are loose Check all the electrical connections The pressure switch shut off pressure is set too high Replace the pressure...

Page 24: ...24 Service Parts Compressor MODEL HS518102 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 30 28 29 31 32...

Page 25: ...ut ST033001AV 1 18 Exhaust tube HS015200AP 1 19 Compression fitting ST072019AV 1 20 Air filter DP500056AV 1 21 Pump HS7101 1 22 Hex head screw ST016000AV 4 23 Washer ST077303AV 4 24 Nut 4 25 Beltguard...

Page 26: ...Service Parts Pump MODEL HS050000AV 6 1 2 3 4 5 7 8 10 9 11 13 12 14 15 16 17 18 19 20 21 22 2 23 3 31 29 30 26 24 25 28 27 32 35 33 34 36 37 38 44 43 39 41 42 48 45 46 47 49 50 51 52 53 54 55 56 57...

Page 27: ...ng 1 34 Compression ring 1 35 Oil ring 2 36 Piston 1 37 Wrist pin 1 38 Retainer clip 2 39 Ball bearing 1 Service Parts Pump continued Part Description Part Number Qty 40 Key 1 41 Dipper retaining scre...

Page 28: ...s problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use Document Number IN56480...

Reviews: