Husky H4140 Operations & Parts Manual Download Page 7

Model No. H4140

Sólo use cubos diseñados para herramientas de impacto. El

uso de cubos para herramientas manuales puede ser peligroso

y ocasionar lesiones físicas. Siempre revise los accesorios en

busca de desgaste, grietas y otros defectos antes del uso.

Llave de impacto de 1/2"

Para obtener repuestos o conocer el centro de servicio

más cercano, llame gratis al 1-877-841-9438

 

No.Ref.   No. Pieza

Descripción

No.Ref.     No. Pieza           Descripción

1

414049

Carcasa del motor

2

414002

Tapón de aceite

3

414003

Sello anular

4

414004

Sello anular (2)

5

414005

Buje del acelerador

6

414006

Tapa del tope

7

414007

Disparador del acelerador

8

414008

Tornillo de terraja (2)

11

414011

Vástago de válvula

12

414012

Resorte de válvula

13

414013

Deflector de escape

14

414014

Adaptador de manguera

15

414015

Rodamiento de bola (2)

16

414016

Sello de aceite

17

414017

Sello anular

18

414018

Placa delantera

19

414019

Cilindro

20

414020

Rotor

21

414021

Aspa del rotor (6)

22

414022

Placa posterior

23

414023

Pasador guía

24

414024

Anillo C

25

414025

Empaque

26

414026

Tapa del extremo

27

414027

Sello anular

28

414050

Regulador de aire

29

414029

Resorte

30

414051

Pasador de tope

31

414031

Tornillo Torx cabeza de botón c/arandela (8)

32

414032

Jaula del martillo

33

414033

Piloto de bola de leva

34

414034

Bola de leva

35

414035

Leva del martillo

36

414036

Pasador del martillo (2)

37

414037

Resorte liberador de leva

38

414038

Std. yunque

39

414039

Separador del yunque

40

414040

Sello anular

41

414041

Anillo de cubos

42

414052

Carcasa de acero color negro

43

414043

Sello de aceite

44

414044

Sello anular

46

414046

Goma de la empuñadura

47

414047

Tornillo de la placa de identificación (2)

Summary of Contents for H4140

Page 1: ...ion or very repetitive hand and arm movements can cause injury Stop using any tool if discomfort tingling feeling or pain occurs You should consult your physician before resuming use of the tool 90 PSIG Maximum Husky impact wrenches are designed to operate at an air pressure of 90 pounds per square inch gauge pressure 90 PSIG maximum at the tool Use of higher air pressure can and may cause injury ...

Page 2: ... anvil housing should be checked every 40 hours of operation Remove the oil plug Ref No 2 from the housing and hold tool so the oil port is lower than the anvil housing Drain oil Measure and refill with approximately 1oz 30ml of SAE 30 weight oil Never over fill the anvil mechanism or excessive pressure will be created reducing tool speed and power If the tool becomes sluggish after adding oil rem...

Page 3: ...mer Cage 11 414011 8700361 Valve Stem 33 414033 8572035 Cam Ball Pilot 12 414012 8700362 Valve Spring 34 414034 8572034 Cam Ball 13 414013 8700525 Exhaust Deflector 35 414035 8700096 Hammer Cam 14 414014 8700064 Hose Adapter 36 414036 8700315 Hammer Pin 2 15 414015 8729478 Ball Bearing 2 37 414037 8700098 Cam Release Spring 16 414016 8729477 Oil Seal 38 414038 8572030 Anvil Std 17 414017 8730036 O...

Page 4: ... with air tool oil Check FWD REV switch Check power regulator setting Lifetime Warranty The Home Depot warrants this Husky Air Powered tool to the original user to be free from defects in material and workmanship If you believe that this tool is defective return the tool with proper proof of purchase to The Home Depot store If The Home Depot determines that this Husky Air Powered tool is defective...

Page 5: ...áticas pueden vibrar durante el uso La exposición prolongada a la vibración o los movimientos de las manos o de los brazos muy repetidos pueden producir lesiones Deje de usar cualquier herramienta si siente incomodidad hormigueo o dolor Debe consultar a su doctor antes de volver a usar la herramienta 620 kPa presión atmosférica máximo Ha sido diseñada para operar a 620 kPa sobre la presión atmosfé...

Page 6: ... tapón de aceite Ref No 2 de la carcasa y sostenga la herramienta de tal modo que el orificio del aceite quede más bajo que la carcasa del y unque Drene el aceite Mida y recargue aproximadamente con 1oz 30ml de aceite SAE 30 Nunca llene en exceso el mecanismo del yunque de lo contrario se creará un exceso de presión que reducirá la velocidad y potencia de la herramienta Si la herramienta funciona ...

Page 7: ...lar 18 414018 Placa delantera 19 414019 Cilindro 20 414020 Rotor 21 414021 Aspa del rotor 6 22 414022 Placa posterior 23 414023 Pasador guía 24 414024 Anillo C 25 414025 Empaque 26 414026 Tapa del extremo 27 414027 Sello anular 28 414050 Regulador de aire 29 414029 Resorte 30 414051 Pasador de tope 31 414031 Tornillo Torx cabeza de botón c arandela 8 32 414032 Jaula del martillo 33 414033 Piloto d...