TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION

MOTOR RUNS, BUT THE 

TOOL JAWS WILL NOT 

ADVANCE

Insufficient Hydraulic Oil

Consult Factory for Repair 
Service

Air Block in Hydraulic System

Invert tool to allow air to rise 
towards the top of the oil 
bladder

Defective Hydraulic Circuit

Consult Factory for Repair 
Service

MOTOR RUNS, TOOL JAWS 

ADVANCE, BUT WILL NOT 

BUILD PRESSURE

Insufficient Hydraulic Oil

Consult Factory for Repair 
Service

Defective Suction Valve or 
Bypass Cartridge

Consult Factory for Repair 
Service

MOTOR WILL NOT RUN AT 

ALL

Defective Battery

Charge or Replace Battery

Bad Contact or Loose Battery 
Connections

Check all Connections and 
Wires

Misaligned Switch

Check to Make Sure that 
Switch is Properly Aligned with 
Trigger
Consult Factory for Repair 
Service

TOOL JAWS WILL NOT 

RELEASE

Tool Did Not Complete a Full 
Cycle and Bypass

Press Trigger and allow Tool 
to Bypass, Then Release Tool 
Jaws

Connector is Jammed in Tool 
Jaws

Press and Hold Release Trigger 
While Prying Tool Jaws Apart

Release Trigger is Bent or Mis-
aligned

Consult Factory for Repair 
Service

Summary of Contents for REC-S624CC

Page 1: ...N Brandon Dr Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www huskietools com REC S624CC 8 Ton Cutting Tool Read and understand all of the instructions and safety information in this...

Page 2: ...roducts represents the state of the art tools and are dependable safe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie Tools Please take the time t...

Page 3: ...ls containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone...

Page 4: ...eye protection when operating this tool Failure to wear eye protection could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using...

Page 5: ...R cables up to 477 MCM standard guy wires to 5 8 and ground rods to 5 8 The specially designed flip top latch and rotating head provide exceptional ease of use and maneuverability in tight working qua...

Page 6: ...R 90 1 2 Rebar 60 1 2 Ground Rod 60 3 8 Guy Wire 40 Cutting Capacities ACSR 477 MCM Standard Guy Wire 5 8 EHS Guy Wire 9 16 Ground Rod 5 8 Rebar Sc 40 5 8 Flip Top Latching Head Tested Up to 75kV One...

Page 7: ...flashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occu...

Page 8: ...ed it may be difficult to retract blades If this occurs continue to advance tool and build pressure A series of clicks will be heard while the tool running in a neutral mode This indicates that the to...

Page 9: ...Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not drop or otherwise abuse the battery cartridge 4 Do not leave the cartridge in locations where it will be...

Page 10: ...BREAKDOWN www huskietools com Page 10 800 860 6170...

Page 11: ...ridge EZ 25H 1 59 P 11 Back Up Ring B C 610F 06 2 19 Push Pin 658 06 1 60 P 11 O Ring 610F 07 1 20 Valve Screw SL5 10 1 61 G35 O Ring 658 11 2 21 LP control plug SL5 11 1 62 Retainer SLND 14 1 22 Spri...

Page 12: ...r Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Conne...

Page 13: ...NOTES...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...198 N Brandon Dr Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www huskietools com...

Reviews: