background image

                               

OPERATION MANUAL

OPERATION MANUAL

REC-B6430

REC-B6430: 12 Ton Compression Tool with 1.2” Jaw Opening

Read and understand all of the instructions and safety information 
in this manual before operating or servicing this tool.

195 Internationale Blvd

Glendale Heights, IL 60139

Phone 800-860-6170 

Fax 800-345-3767

www.spartacogroup.com

Summary of Contents for REC-B6430

Page 1: ...pression Tool with 1 2 Jaw Opening Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL...

Page 2: ...resent state of the art tools and be dependable and safe All products will carry an unconditional guarantee to be free from defects and to perform as advertised Please take the time to read this manua...

Page 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Page 4: ...tion when operating this tool Failure to wear eye protec tion could result in serious eye injury from flying debris or hydraulic oil Electric Shock hazard Use proper personal protective equipment when...

Page 5: ...Lithium Ion Batteries 1 Carrying Strap Battery and Charger BP 84 Huskie Tools Lithium Ion Battery CH 94 Huskie Tools Charger This charger can charge the BP 84 BP 82 and BP 80 only Huskie Tools batter...

Page 6: ...ses and larger heavier tools traditionally used in overhead work The REC B6430 accepts all 12 ton U type dies and is capable of 750 MCM copper lugs and 600 MCM copper splices The new 6 series battery...

Page 7: ...lashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occur...

Page 8: ...elect the appropriate size dies for the connector being used 2 Insert half of the die into the C head by sliding it while pressing the release pin Then insert the other half of the die into the ram wh...

Page 9: ...BATTERY CARTRIDGE 1 Do not short circuit the contacts or expose the cartridge to water oil or solvents 2 Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not...

Page 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN 9 50 89 79 I II J 84 J 81...

Page 11: ...w 351 29 1 65 Ram Spring 644 1 UC 37A 22 M3 X 5 Screw 2 66 SL5 16 Auto Suction Screw 2 23 P55A 02 M5 X 8 Screw C P 1 67 SL5 18 Both way plug 2 658 08 24 M3x10 Screw 1 68 SL5 11 LP control plug 2 25 5N...

Page 12: ...Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connect...

Page 13: ...www spartacogroup com 800 860 6170 13 NOTES...

Page 14: ...www spartacogroup com 800 860 6170 14 NOTES...

Page 15: ...www spartacogroup com 800 860 6170 15 NOTES...

Page 16: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Reviews: