TROUBLESHOOTING GUIDE

Symptom/Situation

Probable Cause

Corrective Action

Power indicator (charger) is not 
lit/displayed.  (All stations)

AC power supply cord not con-
nected to wall outlet.
Power supply cord not 
connected to battery charger.

Bad power supply.

Bad fuse.

Check power supply 
connections.

Replace power supply.

Replace fuse.

Power indicator (charger) is not 
lit/displayed. (Single Station/
Fault)

Bad docking station, charger.

Faulty LED.

Do not use station.

Return for repair.
Try another charger.

Battery Rejected indicator is dis-
played. (Amber flashing)

Faulty condition identified.

Over discharge of battery.

Defective Battery.

Remove battery from 
charger and reinsert.
Re-seat docking station.

Allow to sit in charger for 
15 minutes, then reinsert.

Replace battery.

Station goes to ready in a short 
period of time (5-15 minutes).  

Battery is fully charged.

Faulty battery.

New Battery.

Try conditioning battery.

Replace battery.
Remove battery from charger 
and reinsert.

Station will not go into Charge 
mode. (Amber solid indicator)

Charger not seated correctly.

Bad charger.

Defective battery.

Faulty LED.

Re-seat charger.  

Replace charger.

Replace battery.  

Send in for repair.

Battery becomes hot

Defective battery.

Immediately remove battery
from charger and replace.

Power supply shuts down  
temporarily.

Power line surge.

Power will automatically reset.

Summary of Contents for CH-94

Page 1: ...94DC Lithium Ion Charger Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendale Heights IL 60139 Ph...

Page 2: ...fe Trust integrity teamwork and mutual respect these words are something we take to heart here at Huskie Tools Please take the time to read this manual carefully to learn how to correctly operate and...

Page 3: ...roducts Power supply POWERTRON ELECTRONICS CORP E248122 model PA1060 240T1A250 input rated 100 240 Vac 50 60 Hz 1 8A output rated 24 Vdc 2 5A 60W max Operating Temperature Ranges CAUTION Do not charge...

Page 4: ...www spartacogroup com 800 860 6170 4 PARTS CH 94 CH 94DC 1 Single Unit Charger 2 AC Power Cord with Power Supply 2 1 Available in 110V or 220V AC...

Page 5: ...ter an AC cord or its plug If it does not fit into your outlet have a proper outlet installed by a qualified electrician An improper connection can cause an electric shock To reduce the risk of electr...

Page 6: ...ing Faulty condition identified Over discharge of battery Defective Battery Remove battery from charger and reinsert Re seat docking station Allow to sit in charger for 15 minutes then reinsert Replac...

Page 7: ...ry is rejected due to a fault condition Battery Status Display Charging the Battery Insert the battery into its appropriate charger When the battery is inserted the charging system begins the rapid ch...

Page 8: ...tteries in accordance with local hazardous material laws Do not disassemble incinerate modify or short circuit batteries charger or related components Safety Alert Symbol This safety alert symbol indi...

Page 9: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Page 10: ...www spartacogroup com 800 860 6170 10 Notes...

Page 11: ...www spartacogroup com 800 860 6170 11 Notes...

Page 12: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Reviews: