www.spartacogroup.com
800-860-6170
6
TROUBLESHOOTING GUIDE
Symptom/Situation
Probable Cause
Corrective Action
Power indicator (charger) is not
lit/displayed. (All stations)
AC power supply cord not con-
nected to wall outlet.
Power supply cord not
connected to battery charger.
Bad power supply.
Bad fuse.
Check power supply
connections.
Replace power supply.
Replace fuse.
Power indicator (charger) is not
lit/displayed. (Single Station/
Fault)
Bad docking station, charger.
Faulty LED.
Do not use station.
Return for repair.
Try another charger.
Battery Rejected indicator is dis-
played. (Amber flashing)
Faulty condition identified.
Over discharge of battery.
Defective Battery.
Remove battery from
charger and reinsert.
Re-seat docking station.
Allow to sit in charger for
15 minutes, then reinsert.
Replace battery.
Station goes to ready in a short
period of time (5-15 minutes).
Battery is fully charged.
Faulty battery.
New Battery.
Try conditioning battery.
Replace battery.
Remove battery from charger
and reinsert.
Station will not go into Charge
mode. (Amber solid indicator)
Charger not seated correctly.
Bad charger.
Defective battery.
Faulty LED.
Re-seat charger.
Replace charger.
Replace battery.
Send in for repair.
Battery becomes hot
Defective battery.
Immediately remove battery
from charger and replace.
Power supply shuts down
temporarily.
Power line surge.
Power will automatically reset.