FAULT CODE
196
Injection valve - power supply is faulty
Condition
The diagnostic tool is connected and active.
The EFI control unit is connected.
The injection valve is disconnected.
400591-10
400607-11
Injection valve - check the power supply
–
Measure the voltage between the specified points.
Connector
DQ
Pin
1
–
measuring point
Ground(
−
)
Info
For the measurement, the measurement points must be loaded with a 12V/21W bulb.
The value should not vary more than 1V from the battery voltage
"VBAT"
.
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DQ
pin
1
to the next node in the cable harness for an open circuit.
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Injection valve - control line has a short circuit to plus (terminal 30) (
Injection valve - control line has a short circuit to plus (terminal 30)
Condition
Th e diagnostic tool is disconnected.
The EFI control unit is disconnected.
The breakout box is connected to the wiring harness.
The injection valve is disconnected.
600849-01
400607-11
Injection valve - check the control line for a short circuit to plus (terminal 30)
–
Measure the voltage between the specified points.
Break Out Box
DT
Pin
16
–
measuring point
Ground(
−
)
Voltage
< 0.1 V
» If the measured value does not correspond to the specified value:
–
Check the cable from connector
DT
pin
16
to connector
DQ
pin
2
for a short circuit to plus (terminal 30).
» If the measured value corresponds to the specified value:
–
Check the next possible cause:
Injection valve - control line has a short circuit to ignition plus (terminal 15) (