TROUBLESHOOTING
IMPORTANT:
The trouble-shooting and repair procedures listed here should only be
performed by qualified personnel familiar with this equipment.
Use the proper equipment when trouble-shooting!
MAINTENANCE
HURST JAWS OF LIFE® FIRE-RESISTANT HYDRAULIC FLUID
PRECAUTIONARY MEASURES
Avoid contact with eyes, skin and clothing.
Avoid breathing vapors.
Keep container closed.
Use only with adequate ventilation.
Wash thoroughly after handling.
NOTE: This product could be toxic to fish. It should not be dumped, spilled, rinsed or washed into
sewers for public waterways. Dispose of containers in a secure landfill. Emptied container
retains vapor and product residue. Observe all labeled safe-guards until container is destroyed.
EMERGENCY and FIRST AID PROCEDURES
FIRST AID:
IF IN EYES, immediately flush with plenty of water for at least 15 minutes. Call a physician.
IF ON SKIN, immediately flush with plenty of water. Remove contaminated clothing.
Wash clothing before reuse.
IF INHALED, remove to fresh air. If not breathing, give artificial respiration, preferably
mouth-to-mouth. If breathing is difficult, give oxygen. Call a physician.
Daily / After Use Maintenance and Inspection
Inspect carefully for hydraulic leaks
Inspect hoses and couplings for wear and damage
Clean unit with soap and water
Insure that all fasteners are securely fastened
PROBLEM
Rescue tool will not
operate
Rescue tool operates in
the opposite direction
from the operating decal
Rescue tool will not
develop
power
Electric reel will not
rewind
CAUSE
» Reel is not properly connected
to the power unit
» Reel is not properly connected
to the tool or multi-tool manifold
» Reel is not properly connected
to the tool, multi-tool manifold
or the power unit
» Reel is not properly connected
to the tool, multi-tool manifold
or the power unit.
» Hydraulic fluid leak
» Improper wiring
» Circuit breaker has tripped
REMEDY
» Check all connections
» Check all connections
» Check all connections
» Check all connections
» Check all fittings, hoses
and seals
» Check wiring
» Reset circuit breaker