Section 7: Maintenance
Greasing the Output Drive & Output Drive Housing
For proper operation the HH500 should be greased in two locations
every 12 months.
Greasing the Output Drive
1.
Using Hex Key, remove the threaded plug from output
drive.
2. Insert the grease zerk into the output drive threaded hole.
3. Attach a grease pump containing ThrmaPlex Hi-load - Item #70414.