45019-01  •  06/03/11  •  Hunter Fan Company

10-1.   The remote transmitter has individual buttons for turning the 

fan and the light off and on.

10-2.   Use the Light buttons to turn the Light On and Off.
10-3.   Use the Fan buttons to turn the Fan On and Off.
10-4.   When necessary, replace the battery with a 12-volt type 23A, 

MN-21 battery or equivalent.

Steps 10-2 – 10-3

Step 10-4

Light On 

Light Off 

Fan On 

Fan Off 

10 • Operating the Remote Control

Summary of Contents for Type 2 Models

Page 1: ...lso attach your receipt or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No __________________________________________ Date Purchased __________________________________________ Where Purchased English Francias Owner s Guide and Installation Manual ...

Page 2: ...ut Of The Box Makes Installation Fast in 3 Easy Steps 1 Install mounting bracket and make wiring connections 2 Attach EasyLockTM Blades 3 Install bulb s and glass Please follow the detailed installation instructions inside this manual Installation is complete ...

Page 3: ... fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified elect...

Page 4: ...ceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System Fan attaches directly to building structure Fan support system will hold full weight of the fan and light kit Ceiling Hole e outlet box clearance hole is directly below the joist or support brace Outlet Box e outlet box is an UL approved octagonal 4 x 1 1...

Page 5: ...1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor diameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to the sup...

Page 6: ...ncluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance Standard Mounting hangs from the ceiling by a downrod included Angled Mounting recommended for a vaulted or angled ceiling...

Page 7: ...lectric drill with 9 64 bit Standard screwdriver magnetic tip recommended Phillips head screwdriver magnetic tip recommended Wrench or pliers Ladder height dependent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged cont...

Page 8: ...gnment use slotted holes directly across from each other If you are installing the fan on an ANGLED ceiling be sure to orient the hanger bracket as shown in Illustration 2 3 left or right view Note The isolators should be flush against the ceiling 2 4 Place a flat washer on each of the two 3 screws and pass the screws through the slotted holes in the hanger bracket into the pilot holes you drilled...

Page 9: ...e When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the set screw with a wrench or pliers CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod WARNING Do not carry or lift fan by canopy 3 4 Raise th...

Page 10: ...rom the parts sack into the canopy 3 8 Place the canopy trim ring and canopy with washer on top of the fan assembly 3 9 Align the screw holes in the washer with the holes in the adapter Assemble securely with three 8 32 x 1 2 screws 3 10 Raise the fan and place the hook on the hanger bracket through the round hole in the rim of the canopy WARNING Fan may fall if not assembled as directed in these ...

Page 11: ... Leave 3mm 1 8 of space between the support brace and the washer 4 4 Wrap the braided cable around the support brace once creating a complete circle 4 5 Hook the looped end of the cable over the wood screw so that the braided cable lies between the washer and the support brace 4 6 Tighten the loop and secure the screw and washer all the way down to the support brace 4 7 Coil up the excess cable 4 ...

Page 12: ...ontroller will not function For instructions on how to set the jumpers and or DIP switches read the box below Setting Jumpers DIP Switches When two or more fans are located near each other you may desire to have the receiver transmitter for each fan set to a different code so that the operation of one fan does not affect the operation of the other fans In the transmitter you can access the jumpers...

Page 13: ...profile option 6 4 Using the large wire connectors connect the white wire ungrounded and the black wire ungrounded from the ceiling as follows The white common power wire ungrounded from the ceiling to the white wire ungrounded from the receiver marked on white tag COMMON IN The black power wire ungrounded from the ceiling to the black wire ungrounded from the receiver marked on white tag LIVE IN ...

Page 14: ...lices upward and push them carefully back through the ceiling plate into the outlet box 6 7 Spread the wires apart with the ground wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 6 8 Position the receiver in the canopy so that the antenna is close to the edge of the ceiling plate for clear reception ...

Page 15: ... fourth canopy screw in round hole on canopy Securely tighten all four screws 7 5 Using both hands push the canopy trim ring up to the top of the canopy 7 6 Twist canopy trim ring clockwise to secure the canopy Should you need to remove the canopy trim ring follow these steps 1 Twist canopy trim ring counter clockwise until it releases from canopy Steps 7 1 7 2 Canopy Trim Ring Canopy Hanger Brack...

Page 16: ...he blades in place without tools and to remove the blades easily for cleaning 8 1 Open the locking mechanism 8 2 Align the holes in the blade with the blade iron 8 3 Close the locking mechanism securely You will feel it lock into place 8 4 Repeat steps 8 1 through 8 3 until all blades are installed Step 8 1 Step 8 3 Open Close ...

Page 17: ...eration and damage to the product 9 2 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws 9 Completing Your Installation With or Without a Bowl Light Fixture Note In compliance with Canadian energy regulations this ceilin...

Page 18: ...ch the extra pull chain included to the fan pull chain using the breakaway connector You may find the breakaway connector on the end of the extra chain 9 5 Feed the fan and light pull chains as shown in illustration 9 6 Install both Pin Base CFLs 13 Watt Maximum each included into the sockets 9 7 Place the cover plate up against the glass bowl Align the holes in the cover plate with the grommet ho...

Page 19: ...rom inside the lower switch housing Separate the light fixture from the lower switch housing 9 13 Use the dummy terminals included to cover the ends of the black and white wires in the lower switch housing The black wire receives the female dummy terminal and the white wire receives the male dummy terminal 9 14 Install the switch housing cap and plug button to the lower switch housing 9 15 Store t...

Page 20: ...d the light off and on 10 2 Use the Light buttons to turn the Light On and Off 10 3 Use the Fan buttons to turn the Fan On and Off 10 4 When necessary replace the battery with a 12 volt type 23A MN 21 battery or equivalent Steps 10 2 10 3 Step 10 4 Light On Light Off Fan On Fan Off 10 Operating the Remote Control ...

Page 21: ...air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 11 4 For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic ag...

Page 22: ...he fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights shut off suddenly but fan is still operating 1 Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the MAX wattage sticker affixed to the light socket 2 Turn the power to the fan off at the wall swit...

Page 23: ...heEnvironment Congratulations You re saving energy and money while protecting the environment by purchasing this ENERGY STAR qualified Hunter ceiling fan With this purchase you are doing your part to protect the environment In 2010 ENERGY STAR qualified ceiling fans are projected to cut air pollution by more than 500 million pounds Your new ceiling fan has earned the ENERGY STAR label because it m...