background image

41555-011 

10 

Air Purifier Maintenance

Cleaning Your Air Purifier

Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free 

service. 

Follow these steps to properly maintain your air purifier:
  1.  Approximately every 90 days, the outside of the unit should be cleaned with a soft, 

damp cloth. 

  2.  If needed, the front grill can be removed from the unit and cleaned with soapy water. 

Simply remove the pre-filter before exposing the grill to water.

  3.  Follow the instructions in Changing the Pre-Filter and Changing the Filter (pgs. 10 and 

11) to determine when and how to replace the filters.

NOTES: 

•  The air purifier must be unplugged during the cleaning process.
•  Be sure the unit is completely dry before plugging in and using.
•  Never immerse unit in water.

Changing the Pre-Filter

When the Pre-Filter exceeds 1400 hours (refer to Filter Life Counters for additional informa-

tion, pg. 8), the Pre-Filter indicator will turn on as a reminder that you should replace the 

pre-filter. To maintain proper odor-removing capability and overall filtration performance, 

the pre-filter should be changed every 1400 hours (approximately 3 months of use). If 

necessary, the pre-filter can be changed more often. Proper maintenance of the pre-filter 

will help extend the life of the PermaLife

®

 filter. Refer to Obtaining Replacement Filters (pg. 

13) if you need help finding replacement filters. 

To change the pre-filter and reset the Pre-Filter Life Counter:
 

1.  First, turn off and unplug the air purifier.

 

2.  Next, remove the front grill.  Place your fingers under the handle on the grill 

and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).

 

3.  The pre-filter is attached to the inside of the grill with hook tape. Pull gently 

on the pre-filter to remove it. Refer to Fig. 9 (pg. 11).

 

4.  If needed, use a soft damp cloth to wipe off the grill.

 

5.  Install the new pre-filter by placing it in the grill and pressing gently on the 

pre-filter so that it adheres to the hook tape. You may notice a few black par-

ticles coming off the pre-filter. Those particles are part of the odor-removing 

activated carbon and will be collected on the filter during regular use.

Summary of Contents for Permalife 30748

Page 1: ...www hunterfan com Model 30748 41555 01 07 09 2006 2006 Hunter Fan Company Replacement Filter Information Pre Filter 30901 Model 30748 ...

Page 2: ... 4 Display and Control Keys 5 Operation Initial Operation 6 Filter Life Counters 8 Resetting the Air Purifier 8 Using the Ionizer 9 Air Purifier Maintenance Cleaning Your Air Purifier 10 Changing the Pre Filter 10 Cleaning the Filter 11 Obtaining Replacement Filters 13 Troubleshooting Problem and Solutions 14 Technical Support 14 Warranty Information 15 ...

Page 3: ...lean your air purifier follow the instructions in the Maintenance section of this manual pg 10 READ AND SAVE ALL INSTRUCTIONS Introduction Thank you for purchasing the PermaLife Plus Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe The following innovative features ...

Page 4: ...thepurifier theactivatedcarbonpre filterabsorbsodorsandcatches largeparticles Then theairtravelsthroughthe PermaLife filterwherethesmallerparticles are collected Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Finally the clean purified air is released back into the room Dust Irritants Pollen Allergens Odors Bacteria Pet Hair Dan...

Page 5: ...d and turns the unit on and off Pre filter Reset Resets the Carbon Pre Filter Life Counter FILTER RESET Resets the PermaLife Filter Life Counter IONIZER KEY Turns the ionizer on and off Ionizer key Pre Filter Reset key filter re set key PermaLife filter indicator Carbon Pre filter indicator Ionizer indicator speed knob Off Sleep Active Turbo Clean Fig 3 Air Purifier Control Area ...

Page 6: ... place and have not become loose during shipping To check the filters first open the front grill Release the front grill by placing your fingers under the handle on the grill and pull forward then up Refer to Figs 4 and 5 Fig 4 Fig 5 3 Next check the PermaLife filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 Thecarbonpre filt...

Page 7: ... to Figs 6 and 7 NOTE This unit will not operate unless the grill is in the correct position Fig 8 Fig 6 Fig 7 6 Plug the unit into a 120V electrical outlet and turn the SPEED KNOB The air purifier will start with a low blower speed 7 Use the SPEED KNOB to adjust the blower speed to the desired level Off Sleep Active Turbo Clean Refer to Fig 8 tab recess Line up tab with recess in base OFF sleep a...

Page 8: ... values of the Pre Filter and Filter Life Counters are stored in the air purifier s memory The unit may be unplugged and moved or stored without losing the Pre Filter and Filter Counter values To properly track filter usage the Pre Filter and Filter Life Counters should be reset each time the filters are changed Refer to Changing the Pre Filter pg 10 or Cleaning the Filter pg 11 for instructions o...

Page 9: ...articles are also more easily captured by the PermaLife filter as they pass through the PermaLife Air Purification System To ensure the best air circulation in the room we recommend that you place your air purifier six 6 inches away from any walls To turn the ionizer on or off 1 To turn the ionizer on press the ionizer key The Ionizer Indicator will turn on 2 To turn the ionizer off press the Ioni...

Page 10: ...ld replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 1400 hours approximately 3 months of use If necessary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of thePermaLife filter Refer to Obtaining Replacement Filters pg 13 if you need help finding repla...

Page 11: ...ds 2800 hours approximately 4 to 6 months ofuse the Filter Life Counter will display 0 life remaining and the Filter indicator will flash refer to Filter Life Counters for additional information pg 8 This is a reminder that you should check the filter and clean if necessary The proper time to clean the filter depends on usage and the environment Use the following list to help determine if the filt...

Page 12: ...ean 5 Install the filter with arrows pointing towards the unit Refer to Fig 10 Press the filter firmly into the air purifier To avoid damaging the filter media you should press on the frame of the filter only 6 Place the front grill back onto the unit First line up the tab on the bottom of the grill with the recess on the purifier base and then push the top of the grill forward until it is closed ...

Page 13: ...odel number will be listed on the label Then call 1 800 4HUNTER for your nearest retailer or Hunter Customer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To order online visit our Website at www hunterfan com To ensure that you obtain the correct filters please find your model number below that specifies the correct replacement filters Hunter Air Purifier Model No 30748 Pre Filte...

Page 14: ...Indicator is Flashing 4 Unit has reduced air flow or increased noise Problem Solutions Confirm that the unit is plugged in Check the installation of the front grill Reset the air purifier See Resetting the Air Purifier on pg 8 Reset the air purifier See Resetting the Air Purifier on pg 8 The Filter and or Pre Filter Life Counters have reached the estimated usage times Check and replace filters if ...

Page 15: ...D INCLUDING ANY WARRANTY OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PERIOD O...

Page 16: ... COMPANY BE LIABLE FOR DIRECT INDIRECT SPECIAL CONSEQUENTIALORINCIDENTALDAMAGESINEXCESSOFTHEPURCHASEPRICEOFTHEAIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE L...

Page 17: ...se see our Web page at www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 41780 01 Printed in China and Taiwan M AM 4 TEMP ...

Reviews: