fsdfsdf

All wiring must be in accordance with national and local electrical 
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a 
qualified electrician.

Wall switches are not included. Select an acceptable general-use switch 
in accordance with national and local electrical codes.
4-1.  Before attempting installation, make sure the power is still off. 
4-2.  To connect the wires, hold the bare metal leads together and place 

a wire connector over them, then twist clockwise until tight. For 
all these connections use the wire connectors provided.

4-3.  Connect the bare or green ground wire (grounded) from the 

ceiling to the green ground wire (grounded) from the ceiling plate 
and the green ground wire from the fan.

4-4.  Connect the white wire (ungrounded) from the ceiling to the 

white wire (ungrounded) from the fan.

4-5.  Connect the remaining wires as follows:

    Dual Switch Wiring:

 

• The black wire (ungrounded) from the ceiling to the black wire 

(ungrounded) from the fan

• The black/white wire (ungrounded) from the fan to the wire 

(ungrounded) for the wall switch

    Single Switch Wiring:

 

• The black wire (ungrounded) from the ceiling to the black 

(ungrounded) and the black/white wire (ungrounded) from 
the fan 

 

CAUTION:

  Be sure no bare wire or wire strands are visible after 

making connections.

4-6.  Turn the splices upward and push them carefully back through the 

ceiling plate into the outlet box. 

4-7.  Spread the wires apart, with the grounded wires on one side of 

the outlet box and the ungrounded wires on the other side of the 
outlet box.

Single Switch Wiring

Dual Switch Wiring

Wire 

Connector

4 • Wiring the Fan

Summary of Contents for Models

Page 1: ...or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No __________________________________________ Catalog No...

Page 2: ...r housing CautionsandWarnings READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Use only Hunter replacement parts To reduce the risk of personal injury attach the...

Page 3: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Page 4: ...dder height dependent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the moto...

Page 5: ...into the holes in the ceiling plate 2 3 Thread the lead wires from the outlet box down through the hole in the middle of the ceiling plate 2 4 Align the slotted holes in the ceiling plate with the pil...

Page 6: ...n the pipe will still be visible this is normal Securely retighten the setscrew with a wrench or pliers Skip to Step 3 7 CAUTION The adapter has a special coating on the threads Do not remove this coa...

Page 7: ...and the green ground wire from the fan 4 4 Connect the white wire ungrounded from the ceiling to the white wire ungrounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring T...

Page 8: ...canopy one at a time Once all three screws are in tighten them 5 5 Using both hands push the canopy trim ring up to the top of the canopy The canopy trim ring will snap and lock into place Should you...

Page 9: ...slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to s...

Page 10: ...sing with the housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw int...

Page 11: ...connection could cause improper operation and damage to the product 7 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch...

Page 12: ...13 Remove the wire connectors from the white wire and the red wire in the lower switch housing 7 14 Connect the white wire from the lower switch housing to the white wire from the light fixture 7 15...

Page 13: ...n thread the fan pull chain through the hole in the center of the glass bowl 7 19 Thread the light pull chain through the hole in the center of the glass bowl Then Thread the light pull chain throught...

Page 14: ...ith a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 8 5 For cleaning fin...

Page 15: ...ll the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off suppor...

Reviews: