What to Expect with Your Installation

w.1 - To reduce the risk of fire, electrical shock, or personal injury, 
mount fan directly from building structure and/or an outlet 
box marked acceptable for fan support of 31.8 kg and use the 
mounting screws provided with the outlet box.

w.2 - To avoid possible electrical shock, before installing or 
servicing your fan, disconnect the power by turning off the circuit 
breakers to the outlet box and associated wall switch location. If 
you cannot lock the circuit breakers in the off position, securely 
fasten a prominent warning device, such as a tag, to the service 
panel.

w.3 - To reduce the risk of fire, electrical shock, or motor damage, 
use only Hunter Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the blade 
brackets when installing the blade brackets, balancing the blades, or 
cleaning the fan. Do not insert foreign objects in between rotating fan 
blades.

w.5 - This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, or 
people with a lack of experience and knowledge, unless they have 
received instructions regarding the use of the device or under the 
supervision of a person responsible for their safety.

w.6 - It is recommended that children be supervised to ensure that 
they are not using the appliance improperly

c.1 - All wiring must be in accordance with national and local 
electrical codes. If you are unfamiliar with wiring, use a qualified 
electrician.

c.2 - Use only Hunter replacement parts.

You may need a 
friend to help you.

Check box to see 

fan weight

Assess location

0,50 meters

from blade tip to 
nearest wall or 
obstruction

2,3 meters

from bottom 

edge of blade to 

the floor

Know your wiring

If you are unfamiliar 
with wiring, use a 
qualified electrician.

This product conforms to UL Standard 507.

WARNINGS

CAUTIONS

Must be able to 

secure the fan to 

building structure or 

fan-rated outlet box. 

Do not

 use a plastic 

outlet box.

Select a downrod length

1

2

3

Standard Downrod

for ceilings 2,4 -3 meters high

Shorter Downrod

for fans installed close to ceiling

Longer Downrod

for ceilings 3 meters or higher

Use 

ONLY

 Hunter 

Ceiling Fan branded 

accessory light kits.

Summary of Contents for MD506-01

Page 1: ...www ventiladoreshunter com br MD506 01 09 19 14 Hunter Fan Company ENGLISH...

Page 2: ...Important Instructions Keep Instructions for future use...

Page 3: ...in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportuni...

Page 4: ...persons including children with reduced physical sensory or mental capabilities or people with a lack of experience and knowledge unless they have received instructions regarding the use of the devic...

Page 5: ...Ladder Pliers Wire Strippers Screwdrivers Power Drill optional 3 5 mm Drill Bit optional 8 mm Drill Bit optional If mounting to a support structure you will also need these tools Hammer optional 3 MD5...

Page 6: ...ure Ceiling Outlet Box required Carefully choose the installation location that allows for optimal air flow The support structure must be able to support 5 times the weight of the fan The weight of th...

Page 7: ...in securing ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely install...

Page 8: ...downrod can be inserted KEEP Install three upper motor cover screws found in the hardware bag and tighten them securely Upper Motor Cover Screw To assemble the housing to the hanger adapter align the...

Page 9: ...eilings or ceilings 3 m or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for ceilings 2 4 3 m high Option 1 Option 2 Option 3 skip to next page If you need a different do...

Page 10: ...scale The wires can be cut but leave at least 20 cm extending from the top of the downrod Downrod continued If the setscrew is not tightened securely the fan may fall 20 cm 1 cm Hand tighten the downr...

Page 11: ...14 Hunter Fan Company Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the...

Page 12: ...the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the orange wire connectors from the remote control hardware bag connect the blu...

Page 13: ...Canopy Note Fan style may vary Lift the canopy into place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Inser...

Page 14: ...dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes Attach the blade to the motor using the flat washers from the hardware bag and blade...

Page 15: ...h the two partially installed screws and turn the light kit clockwise until the screws are in the narrow ends of the keyholes Thread the 9 pin plug connector from the fan through the light kit Attachm...

Page 16: ...e assembly screws could result in the light fixture falling Thread the 2 pin connector through the wire slot in the the switch housing Wire Slot Install the remaining attachment screw to secure the li...

Page 17: ...y Push excess wiring into the switch housing through the wire slot Align the two screw screw holes and install the switch housing assembly screws found in the hardware bag Wire Slot Attach the LED ass...

Page 18: ...r fan operation instructions Glass Globe Trim Ring Globe Assembly Screw Light Kit continued Place the glass globe into the globe trim ring Align the three holes in the trim ring with the three holes i...

Page 19: ...le remove the two screws holding the switch cover plate Do not remove the cover plate Orient the cradle by lining up the two mounting holes with those on the cover plate Insert and tighten the screws...

Page 20: ...ress the Fan Off button for at least three seconds to initiate the Safe Exit Mode The lights will flash for visual confirmation The lights will stay on 50 brightness for 15 seconds and then begin to d...

Page 21: ...it is on Push the motor reversing switch firmly left or right to ensure that it is engaged Check the circuit breaker to ensure the power is turned on Make sure the blades spin freely Turn off power f...

Page 22: ...amage to the product as a result of its use for purposes other than those specified by Hunter Fan do Brasil or that are incompatible with the purpose of the product c improper installation or installa...

Reviews: