background image

www.HunterFan.com

1.888.830.1326

M3572-01 • 12/01/14 • © Hunter Fan Company

1.888.830.1326

What to Expect with Your Installation

Know your wiring

If you are unfamiliar 
with wiring, use a 

qualified electrician.

You may need a 
friend to help you.

Check box to see 

fan weight

Assess location

30 inches

from blade tip 
to nearest wall 
or obstruction

7 feet

from bottom 

edge of blade 

to the floor

w.1 - To reduce the risk of fire, electrical shock, or 

personal injury, mount fan directly from building 
structure and/or an outlet box marked acceptable for 
fan support of 70 lbs (31.8 kg) and use the mounting 
screws provided with the outlet box.

w.2 - To avoid possible electrical shock, before installing 
or servicing your fan, disconnect the power by turning 
off the circuit breakers to the outlet box and associated 
wall switch location. If you cannot lock the circuit 
breakers in the off position, securely fasten a prominent 
warning device, such as a tag, to the service panel.

w.3 - 

To reduce the risk of fire, electrical shock, or motor 

damage, use only Hunter Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the 
blade brackets when installing the blade brackets, balancing 
the blades, or cleaning the fan. Do not insert foreign objects 
in between rotating fan blades.

c.1 - All wiring must be in accordance with national and 
local electrical codes ANSI/NFPA 70. If you are unfamiliar 

with wiring, use a qualified electrician. 

c.2 - Use only Hunter replacement parts.

Assess ceiling angle

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

CAUTIONS

Must be able to 

secure the fan to 

building structure or 

fan-rated outlet box

2

Ceiling angles greater 
than 34° will require an 
Angled Mounting Kit. 
See page 4 for details.

Summary of Contents for M3572-01

Page 1: ...chasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing a...

Page 2: ...t box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the ri...

Page 3: ...888 830 1326 Tools Needed Ladder Power Drill optional 9 64 Drill Bit optional Screwdrivers Pliers Wire Strippers If mounting to a support structure you will also need these tools 3 M3572 01 12 01 14...

Page 4: ...ons in this manual most common If you have a flat ceiling Hang your fan by the standard downrod included Mounting Options Use Standard Mounting to hang the fan from a flat ceiling Use Angled Mounting...

Page 5: ...chnical Support at 1 888 830 1326 Make sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes i...

Page 6: ...ger Downrod Standard Downrod Option 1 Option 2 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new p...

Page 7: ...od Downrod continued 8 3 8 Tighten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall KEEP 1 888 830 1326 www HunterFan com Tip If you have difficu...

Page 8: ...an Company www HunterFan com Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Le...

Page 9: ...from the fan Connect the white wire grounded from the ceiling to the white wire from the fan Using an orange wire connector from the hardware bag connect the 3 grounding wires green green yellow strip...

Page 10: ...mpany Canopy Lift the canopy into place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Screw Holes Insert the...

Page 11: ...www HunterFan com 1 888 830 1326 Finial Screw the finial onto the threaded rod found at the bottom of the motor assembly 11 M3572 01 12 01 14 Hunter Fan Company...

Page 12: ...ned with the three arms of the blade ring as shown in the illustration Lift a blade ring to the motor assembly and align the screw holes If you wish to install your fan with three blades skip to the n...

Page 13: ...ades are shielded with Dust Armor which is a nanotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes 13 At...

Page 14: ...from the wall control to a black wire from the switch box Note If two white wires are present in the switch box connect them to each other if they are not already connected Insert the wall control int...

Page 15: ...l control and mount the faceplate not included to the wall control using the two 6 32 screws you removed earlier from the faceplate Reattach the knob onto the wall control and turn it to the left for...

Page 16: ...revent scratching Cleaning products may damage the finishes To change the direction of air flow move the reverse switch to the opposite position Reverse Switch The knob on the wall control unit contro...

Page 17: ...ling The air movement created by a Hunter ceiling fan lets you set your thermostat higher and still stay comfortable Every degree you raise the thermostat saves up to 7 on energy costs So you can cut...