background image

43003-01 

14 

Air Purifier Maintenance

 

15 

43003-01

Air Purifier Maintenance

 

6. Carefully twist the UVC Lamp until the lamp’s copper prongs are visible 

in the Lamp Sockets. Then, carefully remove the Lamp from the unit. 

Refer to Fig. 13. NOTE: HANDLE THE UVC LAMP CAREFULLY. IT MAY 

SHATTER IF IT IS DROPPED.

Fig. 13

LOOK FOR 

LAMP’S COPPER 

PRONGS

 

7. Carefully remove the Lamp from the unit. Refer to Fig. 14.

Fig. 14

 

8. Carefully  insert  the  new  UVC  Lamp’s  copper  prongs  into  the  Lamp 

Sockets, and twist the Lamp until it is securely in place.

 

9. Position the Lamp Cover over the Lamp, and slide it downward until it 

is sceurely in place. NOTE: THE UNIT WILL NOT OPERATE IF THE 

LAMP COVER IS NOT INSTALLED CORRECTLY.

 

10. Install the Lamp Cover Screws.

 

11. Press the filter firmly into the Air Purifier. To avoid damaging the filter 

media, you should press on the frame of the filter only. Refer to page 

12. NOTE: THIS UNIT WILL NOT OPERATE UNLESS FILTER IS IN

-

STALLED CORRECTLY AND SEATED PROPERLY.

 

12. Place the Front Grill back onto the unit. First, line up the tab on the bot

-

tom of the Grill with the recess on the purifier base and then push the 

top of the Grill forward until it is closed. Refer to Figs. 6 and 7, pg. 7. 

NOTE: THIS UNIT WILL NOT OPERATE UNLESS THE FRONT GRILL 

IS INSTALLED CORRECTLY. 

 

12. Plug in the unit and turn it on. If the unit does not operate, check the 

installation of the Lamp Cover and the Front Grill.

 

5. Carefully lift the Lamp Cover Straight up, and remove it from the unit. 

Refer to Figs 12A and 12b.

Fig. 12A

Fig. 12b

Summary of Contents for HEPAtech Plus 30760

Page 1: ... 01 24 2008 2008 Hunter Fan Company HEPAtech Plus Air Purifier Model 30760 Replacement Filter Information Pre Filter 30901 HEPAtech Filter 30963 Replacement UVC Lamp Information www hunterfan com Model 30760 UVC Lamp 30899 ...

Page 2: ... section of this manual pg 10 8 This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that could result in flashover or risk of fire Introduction Thank you for purchasing the HEPAtech Plus Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to impro...

Page 3: ...ctivated carbon Pre Filter absorbs odors and catches large particles Then the air travels through the HEPAtech filter where the smaller particles are collected Next the air passes through the UVC Field which helps reduce airborne pathogens such as germs viruses mold and mildew Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Final...

Page 4: ...during shipping To check the filters first open the Front Grill Release the Front Grill by placing your fingers under the handle on the Grill and pull forward then up Refer to Figs 4 and 5 Fig 4 Fig 5 3 Next check the HEPAtech filter by pressing firmly on all four corners of the Filter to ensure that it is fully inserted into the filter opening NOTE THIS UNIT WILL NOT OPERATE UNLESS FILTER IS INST...

Page 5: ...tructions on how to reset the counters Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the Air Purifier If you still have problems after resetting the Air Purifier please contact Hunter for additional assistance refer to Technical Support pg 17 To Reset the Air Purifier 1 Unplug the unit for at least 30 seconds 2...

Page 6: ...f the Grill with hook tape Pull gently on the Pre Filter to remove it Refer to Fig 9 4 If needed use a soft damp cloth to wipe off the Grill 5 Install the new Pre Filter by placing it in the Grill and pressing gently on the Pre Filter so that it adheres to the hook tape You may notice a few black particles coming off the Pre Filter Those particles are part of the odor removing activated carbon and...

Page 7: ...l not operate unless the Grill is in the correct position 6 Plug in the unit 7 To reset the counter to zero hours and turn off the indicator simply press and hold the Filter Reset key for three seconds Then you must release the Filter Reset key and then press and hold the Filter Reset key again for three seconds to turn off the Filter Indicator Fig 10 Changing the UVC Lamp When the UVC Lamp exceed...

Page 8: ...HE LAMP COVER IS NOT INSTALLED CORRECTLY 10 Install the Lamp Cover Screws 11 Press the filter firmly into the Air Purifier To avoid damaging the filter media you should press on the frame of the filter only Refer to page 12 NOTE THIS UNIT WILL NOT OPERATE UNLESS FILTER IS IN STALLED CORRECTLY AND SEATED PROPERLY 12 Place the Front Grill back onto the unit First line up the tab on the bot tom of th...

Page 9: ... the Pre Filter on pg 10 and Changing the Filter on pg 11 4 Unit has reduced air flow or increased noise The filter is clogged and should be changed Refer to Changing the Filter on pg 11 Obtaining Replacement Filters and UVC Lamps To obtain replacement filters for your Air Purifier first determine your model number by looking at the information label on the back of the Air Purifier The model numbe...

Page 10: ... were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling modifications or damage to the Air Purifier while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance This warranty does not cover Air Purifiers used in commercial applications There are no express or implied warranties as to comm...

Page 11: ... see our Web page at www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 43003 01 Printed in China and Taiwan M AM 4 TEMP ...