1. Take the air purifier out of the box and 

remove the clear plastic protective bag and 

place the unit on a firm level surface.

2. Before turning on the air purifier, you 

need to confirm that the filters are firmly in 

place and have not become loose during 

shipping. To check the filters, open the front 

grill by turning the grill knob until the notch 

above the Hunter logo aligns with the 

unlock symbol on the grill. Figure 1. 

USING YOUR AIR PURIFIER

1. This Air Purifier is designed for use on 

a flat, level surface and may not work 

properly on an uneven surface. ALWAYS 

place this Air Purifier on a firm, level 

surface. ALWAYS place the Air Purifier at 

least six (6) inches away from walls and 

three (3) Ft. from heat sources such as 

stoves, radiators, or heaters.

2. Place the Air Purifier in an area that is out 

of the reach of children.

3. Before using the Air Purifier, extend the 

cord and inspect for any signs of damage. 

DO NOT use the product if the cord has 

been damaged.

4. To reduce the risk of electric shock, this 

product has a polarized plug (one blade is 

wider than the other) as a safety feature. 

This plug will fit into a polarized outlet only 

one way. If the plug does not fit fully into 

the outlet, reverse the plug. If it still does 

not fit, contact a qualified electrician. DO 

NOT attempt to defeat or override this 

safety feature.

5. ALWAYS UNPLUG the Air Purifier when it 

is not in operation, while the filter is being 

changed, and while it is being cleaned.

6. DO NOT tilt or move the Air Purifier while it 

is in operation. Shut off and unplug before 

moving.

7. DO NOT immerse the Air Purifier in water 

as permanent damage will occur. Refer to 

and follow the CLEANING AND FILTER 

REPLACEMENT instructions.

8. DO NOT run the ionizer if tobacco smoke, 

air fresheners, dripless wax candles, or 

grease from cooking is present. 

 Save These Important Instructions

SAFETY INSTRUCTIONS

La

tche

s

Ar

m

s

Figure 2.

4. The carbon pre-filter is mounted inside the 

front of the unit with hook tape. Confirm 

that it properly covers the grill vents. You 

may notice a few black particles coming off 

the pre-filter. Those particles are part of the 

odor-removing activated carbon and will be 

collected on the filter during use. 

5. The HEPAtech

®

 filter will be resting inside 

the unit. If present, remove the plastic bag 

surrounding the filter and place the filter 

back into the Air Purifier. The  filter should 

Figure 1.

3. Open the door outward until the latches 

holding the front grill easily slide away from 

the arms holding them. Figure 2.

Summary of Contents for HEPAtech 30708

Page 1: ...HEPAtech HEPAtech HEPAtech 44093 01 20111021 2011 Hunter Fan Co English Air Purifier Owner s Manual Model 30708 ...

Page 2: ...rbon pre filter helps remove odors such as cooking smoke and pet smells from the air It also traps lint hair and other large particles to help extend the life and performance of the HEPAtech filter Ionizer The ionizer improves the quality of air in the room by releasing negative ions into the air that attract positively charged dust smoke and pollen particles Filter Calendar Filter maintenance is ...

Page 3: ... outlet only one way If the plug does not fit fully into the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat or override this safety feature 5 ALWAYS UNPLUG the Air Purifier when it is not in operation while the filter is being changed and while it is being cleaned 6 DO NOT tilt or move the Air Purifier while it is in operation Shut off and...

Page 4: ... causing particles and traps them on the pre filter Smaller particles such as dust mold and pollen pass through the pre filter and are captured by the HEPAtech filter Up to 99 97 of particles as small as 1 microns can be captured HOW THE HEPATECH SYSTEM WORKS Figure 3 Flat Disk Side Side Notch HEPAtech Filter Pre Filter Front Grill Ionizer Figure 4 Figure 6 Horizontal Vertical The ionizer charges ...

Page 5: ...he HEPAtech filter is checked in February then the filter would need to be checked again in August Figure 9 pre filter The inspection symbol on the outer knob points to the month in which you should check the pre filter for wear The pre filter is designed for 3 months of usage Replacing or checking the pre filter in May means the filter would need to be checked again in August Figure 8 6 Months 3 ...

Page 6: ...d local taxes may apply Prices are subject to change without notice All orders will be shipped USPS or UPS Ground allow 12 15 working days for delivery Filter Type 30912 Hepatech w Microban 30901 Pre Filter NOTE To avoid the risk of electric shock always unplug the unit before cleaning 1 Clean the outside of the unit with a soft damp cloth The front grill can be cleaned in soapy water after it has...

Page 7: ...ns or damage to the Air Purifier while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance This warranty does not cover Air Purifiers used in commercial applications There are no express or implied warranties as to commercial purchasers or users To obtain service contact the nearest Hunter authorized service center or the Hunter Fan Company Serv...

Page 8: ...Humidifiers Air Purifiers Thermostats Bath Fans Ceiling Fans Home Convenience To learn more about Hunter Fan Company products please see our webpage at www hunterfan com Fan Company 7130 Goodlett Farms Pkwy Suite 400 Memphis Tennessee 38016 Printed in China and Taiwan ...

Reviews: