Air Purifier Maintenance

 

6.  Install the grill back onto the unit. First, line up the tabs on the bottom of the 

grill with the openings on the purifier base and then push the top of the grill 

forward until it is closed. 

 

7.  Plug in the air purifier. NOTE: This unit will not operate unless the grill is in the 

correct position. 

 

8.  Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET key for 2 

seconds. The Pre-Filter Counter will return to 100% and the Pre-Filter indicator 

will stop flashing.

Changing the Filter

When the filter exceeds 2800 hours (approximately 3-6 months of use), the Filter Life Counter 

will display 0% life remaining and the Filter indicator will flash (refer to Filter Life Counters 

for additional information, pg. 9). This is a reminder that you should check the filter and 

replace if necessary. The proper time to change the filter depends on usage and the envi-

ronment. Use the following list to help determine if the filter should be changed:

•  Compare the color of the filter to the color coded chart on the inside of the housing. If 

the filter color matches the darkest color on the chart, you should replace the filter.

•  If you notice a decrease in air output or an increase in noise at any time during normal 

operation, the filter may be clogged. Replace the filter to return to normal operation.

To change the filter and reset the Filter Life Counter: 
 

1.  First, turn off and unplug the air purifier.

 

2.  Next, remove the front grill. Place your fingers in the recesses on either side of 

the top of the grill and pull firmly. 

 

3.  Gently pull on the filter to remove it from the unit. While removing the filter, 

note the directional arrows printed on the side of the filter. The new filter will 

be installed with the same orientation. Once removed, the used filter can be 

discarded. 

 

4.  Remove the new filter from its wrapping and look at the directional arrows 

printed on the side of the filter. Install the filter with arrows pointing towards 

the unit. Press the filter firmly into the air purifier. To avoid damaging the filter 

media, you should press on the frame of the filter only.

 

5.  Reinstall the grill by first lining up the tabs on the bottom of the grill with the 

openings on the air purifier base and then pushing the top of the grill forward 

until it is closed. 

Continued

Summary of Contents for HEPAtech 30527

Page 1: ...www hunterfan com 41998 01 06 23 2006 2006 Hunter Fan Company HEPAtech Air Purifier Models 30527 30528 Replacement Filter Information Model 30527 30528 Pre Filter 30901 30901 HEPAtech Filter 30931 30931 ...

Page 2: ... 5 Operation Initial Operation 6 Using the Ionizer 7 Remote Operation 8 Filter Life Counters 9 Locking Unlocking the Keypad 10 Resetting the Air Purifier 10 Air Purifier Maintenance Cleaning Your Air Purifier 11 Changing the Pre Filter 11 Changing the Filter 12 Obtaining Replacement Filters 13 Troubleshooting Problems and Solutions 14 Technical Support 14 Warranty Information 15 ...

Page 3: ...o properly clean your air purifier follow the instructions in the Maintenance section of this manual pg 10 READ AND SAVE ALL INSTRUCTIONS Introduction Thank you for purchasing the HEPAtech Air Purifier from Hunter Fan Company You have pur chased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe The following innovative fe...

Page 4: ...releases negative ions into the air that attract positively charged dust smoke and pollen particles Finally the clean purified air is released back into the room Air Purifier Components Fig 2 Air Purifier Components Fig 3 Inside Surface of Front Grill Hook Tape Grill Hook Tape HEPAtech Filter Pre Filter Control area Front Grill Fig 1 Illustration of the Air Filtration System Dust Irritants Pollen ...

Page 5: ...justs the blower speed and turns the unit on and off Pre filter Reset Resets the Carbon Pre Filter Life Counter FILTER RESET Resets the HEPAtech Filter Life Counter Fig 4 Air Purifier Control Area and Alpha numeric Display Animated Blower HEPAtech filter life counter keypad locked indicator Blower Speed carbon pre filter indicator HEPAtech filter indicator pre filter life counter Ionizer indicator...

Page 6: ...l will rest open at about 45º You can remove the front grill by placing your fingers under the handle and pulling the front grill towards you and then up Fig 5 Fig 6 Pull Forward then up handle 3 Next check the HEPAtech filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 The carbon pre filter is mounted inside the front grill wi...

Page 7: ...pollen particles are attracted to the negative ions These particles settle out of the air and can be vacuumed up during normal cleaning These particles are also more easily captured by the HEPAtech filter as they pass through the HEPAtech Air Purification System To ensure the best air circulation in the room we recommend that you place your air purifier six 6 inches away from any walls To turn the...

Page 8: ...ndnewbatteries Donotmixalkaline standard carbon zinc or rechargeable nickel cadmium batteries 2 To use the remote point it at the air purifier then press and release the appropriate key The key functions are as follows 0 OFF 1 LOW 2 MEDIUM and 3 HIGH When using the remote the air purifier remains in the mode that it is currently set for When the keypad is locked the remote may still be used to adj...

Page 9: ...ble below gives typical usage times of the filters Table 2 Typical Usage Times of the Filters The display shows the percentage of life left since the counter was reset NOTE The per centage level drops in 5 increments The values of the Pre Filter and Filter Life Counters are stored in the air purifier s memory The unit may be unplugged and moved or stored without losing the Pre Filter and Filter Co...

Page 10: ...icator will appear on the display Refer to Fig 9 After releasing the keys the Keypad Locked Indicator will disappear 2 Tounlockthekeypad pressandholdtheUP DOWNkeys simultaneouslyfor2 3seconds TheKeypadIndicatorwill disappear and the keypad will be functional Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the air...

Page 11: ...ator will flash as a reminder that you should replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 1400 hours approximately 3 months of use If necessary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of the HEPAtech filter Refer to Obtaining Replacement F...

Page 12: ... the housing If the filter color matches the darkest color on the chart you should replace the filter If you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Replace the filter to return to normal operation To change the filter and reset the Filter Life Counter 1 First turn off and unplug the air purifier 2 Next remove the front ...

Page 13: ...termine your model number by looking at the information label on the back of the air purifier The model number will be listed on the label Then call 1 800 4HUNTER for your nearest retailer or Hunter Customer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To order online visit our Website at www hunterfan com To ensure that you obtain the correct filters please find your model numbe...

Page 14: ...ll Reset the air purifier See Resetting the Air Purifier on pg 10 Key pad has been locked to prevent accidental changes to the programs See Keypad Lock on pg 10 to unlock the key pad Reset the air purifier See Resetting the Air Purifier on pg 10 The Filter and or Pre Filter Life Counters have reached the estimated usage times Check and replace filters if needed Refer to Filter and Pre Filter Count...

Page 15: ...INCLUDING ANY WARRANTY OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PERIOD OF ...

Page 16: ...INEXCESSOFTHEPURCHASEPRICEOFTHEAIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS A...

Page 17: ...s please see our Web page at www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 41599 01 Printed in China and Taiwan ...

Reviews: