Air Purifier Maintenance

6. Place the front grill back onto the unit. First, line up the tabs on the bottom of

the grill with the openings on the purifier base and then push the top of the
grill forward until it is closed. Refer to Figs. 2 and 3 (pg. 4). NOTE: This
unit will not operate unless the grill is in the correct position.

7. Plug in the air purifier.

8. Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET

key for 2 seconds. The Pre-Filter Counter will return to 100% and the Pre-
Filter indicator will stop flashing.

Changing the Filter

When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter Life
Counter will display 0% life remaining and the Filter indicator will flash (refer to Filter Life
Counters for additional information, pg. 7). This is a reminder that you should check the
filter and replace if necessary. The proper time to change the filter depends on usage and the
environment. Use the following list to help determine if the filter should be changed:

• Compare the color of the filter to the color coded chart on the inside of the housing. If the

filter color matches the darkest color on the chart, you should replace the filter.

• If you notice a decrease in air output or an increase in noise at any time during normal

operation, the filter may be clogged. Replace the filter to return to normal operation.

To change the filter and reset the Filter Life Counter:

1. First, turn off and unplug the air purifier.

2. Next, remove the front grill.  Place your fingers in the recesses on either side of the

top of the grill and pull firmly. Refer to Figs. 2 and 3 (pg. 4).

3. Gently pull on the filter to remove it from the unit. While removing the filter,

note the directional arrows printed on the top of the filter. The new filter will be
installed with the same orientation. Once removed, the used filter can be dis-
carded.

4. Remove the new filter from its wrapping and look at the directional arrows

printed on the side of the filter. Install the filter with arrows pointing towards
the unit. Press the filter firmly into the air purifier. To avoid damaging the
filter media, you should press on the frame of the filter only.

5. Place the front grill back onto the unit. First, line up the tabs on the bottom of

the grill with the openings on the purifier base and then push the top of the
grill forward until it is closed. Refer to Figs. 2 and 3 (pg. 4). NOTE: This
unit will not operate unless the grill is in the correct position.

41773-01.pmd

4/15/05, 10:54 AM

10

Summary of Contents for HEPATECH 30378

Page 1: ...ls 30378 30379 41773 01 04 15 2005 2005 Hunter Fan Company HEPAtech Air Purification System Replacement Filter Information Pre Filter 30901 30901 HEPAtech Filter 30931 30931 Model 30378 30379 41773 01 pmd 4 15 05 10 54 AM 1 ...

Page 2: ...Operation Initial Operation 6 Filter Life Counters 7 Locking Unlocking the Keypad 7 Resetting the Air Purifier 8 Using the Ionizer 8 Air Purifier Maintenance Cleaning Your Air Purifier 9 Changing the Pre Filter 9 Changing the Filter 10 Obtaining Replacement Filters 11 Troubleshooting Problem and Solutions 12 Technical Support 12 Warranty Information 13 41773 01 pmd 4 15 05 10 54 AM 2 ...

Page 3: ...ier follow the instructions in the Maintenance section of this manual pg 9 READ AND SAVE ALL INSTRUCTIONS Introduction Thank you for purchasing the HEPAtech Air Purification System from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe The following innovative features are included in...

Page 4: ...ticles are collected Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Finally the clean purified air is released back into the room Dust Irritants Pollen Allergens Odors Bacteria Pet Hair Dander Carbon Pre filter HEPAtech Filter 99 97 1 Microns Ionizer Fig 2 Air Purifier Components CONTROL AREA HEPAtech FILTER PRE FILTER RECESS FO...

Page 5: ...n Pre Filter Life Counter FILTER RESET Resets the HEPAtech Filter Life Counter IONIZER KEY Turns the ionizer on and off Fig 4 Air Purifier Alpha numeric Display and Control Area HEPAtech FILTER LIFE COUNTER IONIZER INDICATOR KEYPAD LOCKED INDICATOR UP DOWN KEYS IONIZER KEY PRE FILTER RESET KEY FILTER RESET KEY ANIMATED BLOWER BLOWER SPEED PRE FILTER LIFE COUNTER HEPAtech FILTER INDICATOR CARBON PR...

Page 6: ...mly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 The carbon pre filter is mounted inside the front grill with hook tape Confirm that it properly covers the grill vents You may notice a few black particles com ing off the pre filter Those particles are part of the odor removing activated car bon and will be collected on the filter during use 5 Plac...

Page 7: ...osing the Pre Filter and Filter Counter values To properly track filter usage the Pre Filter and Filter Life Counters should be reset each time the filters are changed Refer to Changing the Pre Filter pg 9 or Changing the Filter pg 10 for instructions on how to reset the counters Locking Unlocking the Keypad Once you enter the desired speed you may want to lock the keypad to prevent accidental cha...

Page 8: ...sed into the air and positively charged dust smoke and pollen particles are attracted to the negative ions These particles settle out of the air and can be vacuumed up during normal cleaning These particles are also more easily captured by the HEPAtech filter as they pass through the HEPAtech Air Purification System To ensure the best air circulation in the room we recommend that you place your ai...

Page 9: ...ld replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 1400 hours approximately 3 months of use If necessary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of the HEPAtech filter Refer to Obtaining Replacement Filters pg 11 if you need help find ing repl...

Page 10: ... on the chart you should replace the filter If you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Replace the filter to return to normal operation To change the filter and reset the Filter Life Counter 1 First turn off and unplug the air purifier 2 Next remove the front grill Place your fingers in the recesses on either side of...

Page 11: ... on the back of the air purifier The model number will be listed on the label Then call 1 800 4HUNTER for your nearest retailer or Hunter Cus tomer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To order online visit our Website at www hunterfan com To ensure that you obtain the correct filters please find your model number below that specifies the correct replacement filters Hunte...

Page 12: ...that the unit is plugged in Check the installation of the front grill Reset the air purifier See Resetting the Air Purifier on pg 8 Key pad has been locked to prevent accidental changes to the programs See Keypad Lock on pg 7 to unlock the key pad Reset the air purifier See Resetting the Air Purifier on pg 8 The Filter and or Pre Filter Life Counters have reached the estimated usage times Check an...

Page 13: ...ANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DU RATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO THE MOTOR IS EXPRESSLY ...

Page 14: ...EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT INDI RECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE AIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCI DENTAL OR ...

Page 15: ... at www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 41773 01 Printed in China and Taiwan M AM 4 TEMP 41773 01 pmd 4 15 05 10 54 AM 15 ...