HUNTER ICC QUICK CHECK AND RESET FEATURES
Clearing Non Volatile Memory:
Turn the dial to
RUN
Press the
,
,
and
buttons down simultaneously.
Whilst the 3 buttons are being held down, momentarily press and release the
RESET
button
Release the
,
,
and
buttons. The LCD display will show 12.00am
Test Program:
The ICC allows the user a simplified method for running a test program. This feature operates each
station in numerical sequence, from the lowest to the highest. You can start with any station. This is a
great feature to check the operation of your irrigation system.
To initiate the test program:
Press and hold the
button. The station number will be flashing.
Press the
or
button to scroll to the station you would like the test program to start with. Use
the
or
button to set the run time up to 15 minutes. The run time needs to be entered only once.
After a 2 second pause, the test program will begin.
Hunter Quick Check™:
Irrigation professionals are continuously looking for ways to more efficiently and effectively diagnose
programs in the field. Instead of having to physically check each field wiring circuit for potential
problems, the user can run the Hunter Quick Check™ circuit test procedure. This circuit diagnostic
procedure is very beneficial because of its ability to aid in quickly identifying “shorts” commonly caused
by faulty solenoids or when a bare common wire touches a bare station control wire.