Page 1: ...HUNTER CONTROLLERS TROUBLESHOOTING AND WARRANTY FOR ONLINE EXAMPLES GO TO HTTP WWW HUNTERINDUSTRIES COM SUPPORT TRAININGVIDEOS ...

Page 2: ...C TROUBLESHOOTING o PRO C PCC QUICK CHECK AND RESET FEATURES ICC TROUBLESHOOTING o ICC QUICK CHECK AND RESET FEATURES I CORE TROUBLESHOOTING o I CORE QUICK CHECK I CORE DUAL TROUBLESHOOTING NODE o ADVANCED PROGRAMMING FEATURES TROUBLESHOOTING ACC TROUBLESHOOTING SOLAR SYNC TROUBLESHOOTING o CALIBRATION SET UP SOLAR SYNC APPLICATIONS CHART HUNTER CONTROLLERS COMPARISON ...

Page 3: ... 5 Not Warranty if an indoor controller is installed outdoors 6 Not Warranty if mistreated or damaged by the customer STEP 2 Please ensure you have checked the relevant controller Reset Quick Check Quick Test and Troubleshooting Guide attached STEP 3 If Warranty still applies please complete the following Dealer Contractor Date of purchase Sales Representative If out of Warranty please talk to you...

Page 4: ...emove jumper from the sensor terminals Stations have been programmed to override the sensor Reprogram the sensor override to enable the sensor Frozen display or showing incorrect information Power Surge Reset the controller Display shows a station is running but the umbrella and sprinkler icons are flashing The sensor is interrupting irrigation however the station has been programmed to override t...

Page 5: ...Memory The XC is capable of saving the preferred watering program into memory for retrieval at a later time This feature allows for a quick way of resetting the controller to the original programmed watering schedule To save the program into the memory With the dial in the RUN position press and hold the and buttons for 5 seconds The display will scroll three segments from left to right across the...

Page 6: ...tart with the dial in the RUN position Press and hold the button down while turning the dial to the RUN TIMES position Release the button At this point the display will show a delay time for all stations in seconds which will be flashing Press the or buttons to increase or decrease the delay time between 20 seconds and 4 hours Return the dial to the RUN position ...

Page 7: ...icated Check wire circuit or solenoid for the valve number indicated Repair short or replace solenoid Press any button to clear the ERR from the display Frozen display or showing incorrect information Power Surge Reset the controller Display shows P ERR Faulty pump relay or master valve wiring Check wiring to relay or master valve solenoid Press any button to clear the error Incompatible or defect...

Page 8: ...t be changed manually The Solar Sync sensor need to he uninstalled if permanently removing it from the controller After removing the Solar Sync sensor from the controller turn the knob to Solar Sync Settings The screen should show dashed lines The sensor is now uninstalled Display shows no SS Solar Sync sensor has been disconnected from controller but is not uninstalled Check Solar Sync sensor wir...

Page 9: ... Memory The X Core is capable of saving the preferred watering program into memory for retrieval at a later time This feature allows for a quick way of resetting the controller to the original programmed watering schedule To save the program into the memory With the dial in the RUN position press and hold the and buttons for 5 seconds The display will scroll three segments from left to right acros...

Page 10: ...on Start with the dial in the RUN position Press and hold the button down while turning the dial to the RUN TIMES position Release the button At this point the display will show a delay time for all stations in seconds which will be flashing Press the or buttons to increase or decrease the delay time between 0 and 4 hours Return the dial to the RUN position ...

Page 11: ...ading to that station Check the station wire for continuity Replace or repair shorted wire Check that all wire connections are good and water tight The display reads NO AC There is no AC power present the controller is not receiving power Check to see if the transformer is properly installed The display reads SENSOR OFF The rain sensor is interrupting irrigation or the sensor jumper is not install...

Page 12: ...r dial in incorrect position Be sure the dial is in correct position Total number of stations can be easily checked by placing dial in SET STATION RUN TIMES position and pressing the back arrow The controller is continuously watering even when it should not be on Cycling repeatedly Too many start times user error Only one start time per active program is required Refer to Setting Watering Start Ti...

Page 13: ... display indicating the program is being saved into memory Release the and buttons Hunter Quick Check This circuit diagnostic procedure is can quickly identify shorts commonly caused by faulty solenoids or when a bare common wire touches a bare station control wire To initiate the Hunter Quick Check test procedure Press the and buttons simultaneously In the standby mode the LCD will display all se...

Page 14: ...ory defaults and erase all programs and data that have been entered into the controller Press and hold the button Press and release the RESET button on the back of the front panel Wait until the display shows 12 00am Release the button All the memory has been cleared and the controller may now be reprogrammed ...

Page 15: ...nsformer is properly installed The display reads SEN OFF The rain sensor is interrupting irrigation or not installed Slide the Rain Sensor switch on front panel to the OFF position to bypass rain sensor circuit The Controller does not start automatically Potential user programming error Check to make sure start time is entered correctly note AM PM setting as well Check to make sure watering day is...

Page 16: ...Controller receiving voltage too low for valve operation Check and correct 110 or 220 volt connection The controller is continuously watering even when it should not be on Too many start times Only one start time per active program is required There are not enough start times for all stations User error The controller has eight start times per program Review Programming Fundamentals to understand ...

Page 17: ...old the button The station number will be flashing Press the or button to scroll to the station you would like the test program to start with Use the or button to set the run time up to 15 minutes The run time needs to be entered only once After a 2 second pause the test program will begin Hunter Quick Check Irrigation professionals are continuously looking for ways to more efficiently and effecti...

Page 18: ...ck test procedure Within seconds the system searches all stations in an effort to detect a high current path through the station terminals When a field wiring short is detected an ERR symbol preceded by the station number will momentarily flash on the controller LCD display After the Hunter Quick Check completes running this circuit diagnostic procedure the controller returns to the automatic wate...

Page 19: ...s not irrigate Field wiring or solenoid problem Perform manual Single Station start and observe display and Station Status light If Station Status light is RED check solenoid and filed wiring including COM wires Station outputs must not exceed 0 56A max The controller does not irrigate automatically Possible programming errors Verify all programs Days to water start times and Station Run Times Sen...

Page 20: ...how in incorrect Module seated incorrectly Verify that modules are seated all the way back in the wiring compartment and module lock is ON Module slot skipped Verify that no module slots have been skipped from left to right Station output module overloaded Swap with known good module in the same position If now module works in the position replace the old module If new known good module also fails...

Page 21: ...on control wire To initiate Hunter Quick Check With the dial in the RUN position press and hold the or buttons for approximately two seconds and then release After a few seconds the display will show a number 1 Press the button The screen will initially show a number 20 and within one second the Hunter Quick check will begin The controller will begin searching all stations in an effort to detect a...

Page 22: ...I CORE DUAL TROUBLESHOOTING ...

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ...NODE ADVANCED FEATURES TROUBLESHOOTING ...

Page 27: ......

Page 28: ......

Page 29: ...formation when diagnosing problems Station does not irrigate Field wiring or solenoid problem Perform manual One Station start and observe display and output light If light red check solenoid and field is wiring including COM common wires Station outputs must not exceed 0 56A total Controller does not irrigate automatically Possible programming errors Verify all programs Days to Water Start Times ...

Page 30: ...ht If new module works replace old module if new known good module also fails to light check gold and silver contacts for dirt corrosion or pests AC fuse blows Incorrect AC wiring Verify that AC connections are correct for AC supply voltage Surge on AC power line Check for lighting damage in vicinity Multiple output module failures Lightning Check and improve earth ground Modules not installed cor...

Page 31: ...adjust is showing on the controller Seasonal Adjustment seems high Region too low Water Adjustment setting too high Make sure controller dial is in the RUN position Decrease value of the water adjustment setting If you decrease the water adjustment feature to one and still require further adjustment decrease the region Solar Sync will immediately update the Seasonal Adjust on the controller If it ...

Page 32: ...updated with the new Seasonal Adjust Increase the Water Adjustment setting until the desired Seasonal Adjust is shown If you max out the Water Adjustment scale at 10 and still require more Seasonal Adjust move down to the next lower Region from Region 4 to 3 for example Seasonal Adjust too high Make sure controller dial is in the Run position Decrease the value on the Water Adjustment scale defaul...

Page 33: ......