Hunter 45039-01 Owner'S Manual And Installation Manual Download Page 7

7

45039-01  •  09/16/09  •  Hunter Fan Company

All wiring must be in accordance with national and local electrical 
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a 
qualified electrician.

Wall switches are not included. Select an acceptable general-use switch 
in accordance with national and local electrical codes.
4-1.  Before attempting installation, make sure the power is still off. 
4-2.  To connect the wires, hold the bare metal leads together and place 

a wire connector over them, then twist clockwise until tight. For 
all these connections use the wire connectors provided.

4-3.  Connect the bare or green ground wire (grounding) from the 

ceiling to the green ground wire (grounding) from the ceiling plate 
and the green ground wire (grounding) from the fan.

4-4.  Connect the white wire (grounded) from the ceiling to the white 

wire (grounded) from the fan.

4-5.  Connect the remaining wires as follows:

    Dual Switch Wiring:

 

• The black wire (ungrounded) from the ceiling to the black wire 

(ungrounded) from the fan

• The black/white wire (ungrounded) from the fan to the wire 

(ungrounded) for the wall switch

    Single Switch Wiring:

 

• The black wire (ungrounded) from the ceiling to the black 

(ungrounded) and the black/white wire (ungrounded) from 
the fan 

 

CAUTION:

  Be sure no bare wire or wire strands are visible after 

making connections.

4-6.  Turn the splices upward and push them carefully back through the 

ceiling plate into the outlet box. 

4-7.  Spread the wires apart, with the grounded wires on one side of 

the outlet box and the ungrounded wires on the other side of the 
outlet box.

Dual Switch Wiring

Single Switch Wiring

Wire 

Connector

4 • Wiring the Fan

Summary of Contents for 45039-01

Page 1: ...lso attach your receipt or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No ______________________________...

Page 2: ...ssible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breaker...

Page 3: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Page 4: ...endent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades...

Page 5: ...ll four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the...

Page 6: ...p to Step 4 7 CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod For Low Prof...

Page 7: ...he green ground wire grounding from the fan 4 4 Connect the white wire grounded from the ceiling to the white wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring T...

Page 8: ...canopy screws into the holes opposite the ceiling plate tabs 5 4 Partially install a canopy screw into the hole between the two ceiling plate tabs When all the holes are properly aligned securely tig...

Page 9: ...slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to s...

Page 10: ...housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing...

Page 11: ...rrect connection could cause improper operation and damage to the product 7 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower sw...

Page 12: ...d the fan pull chain through the grommet hole in the side of the cover plate 7 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 7 12 Thread the ligh...

Page 13: ...ower switch housing 7 18 Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull...

Page 14: ...a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 8 5 For cleaning finish...

Page 15: ...em Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefull...