Hunter 44260 Owner'S Manual Download Page 7

7

®

Auto Recovery

Hunter’s Auto Recovery feature meets the ENERGY STAR

®

 guidelines for energy efficiency by

allowing the heating or cooling system to recover gradually from an energy-saving setpoint
temperature to a comfort setpoint temperature.

Auto Recovery calculates how early to turn your system back On, so that the room temperature is
already comfortable by the start of the comfort temperature program period. Auto Recovery
works in both Heat and Cool modes.

When the thermostat is in Auto Recovery mode, the display
will alternate “RECO” with time, and the program indicator
will flash.

Auto Recovery can be disabled by sliding the Recovery
switch on the circuit board.

Auto Recovery will not operate if Permanent hold or Tempo-
rary hold is in operation.

Auto Recovery can be canceled manually if
HOLD / RETURN is pressed during the recovery process.

Auto Recovery will be canceled and change to Temporary
Manual Override mode if the setpoint is adjusted during the
recovery process.

Error Mode

If the thermostat is unable to control your system due to an
unexpected battery problem, the thermostat will enter Error
Mode. In this condition, the thermostat flashes “Err” on the
LCD display, and shuts off your system. To correct this problem,
replace the batteries with 2 new AA alkaline batteries, even if
you have recently replaced them. Next, use a paper clip to
press the RESET button next to the keypad. You will need to
reprogram your thermostat and confirm normal operation.

If Error Mode returns, please call Hunter Technical support at 1-888-830-1326 for further
information.

Auto Cut Off

Your thermostat will automatically cut-off in Heat mode if the room temperature rises
above 95˚F (35˚C). It will cut-off in Cool mode if the room temperature drops below 40˚F
(4˚C).

Note that if your system has malfunctioned and no longer responds to thermostat controls, the
Auto Cut-Off will have no effect.

TROUBLESHOOTING

HEAT TEMP

2

If you experience any other problems, call 1-888-830-1326 from 8 AM to 5 PM Central Time
for technical assistance.

Problem

Solution

No Display

Entire Display Dims

Program Does Not Change
at your Desired Setting

Auto Fan Does Not
Turn On Properly

Heating or Cooling Does
Not Go On or Off

Erratic Display

If unit continues to operate
in the Off position

Thermostat permanently
reads “HI”, “LO”, or “ERR”

1. Check battery connections and batteries.

2. Press RESET button with a small pin and hold in

for two seconds.

1. Replace Batteries

1. Check that the time is set properly to “AM”

 or “PM”.

2. Check that the thermostat is not in Permanent

HOLD mode.

3. Check for the correct day setting.

1. Move HG/HE selector to correct position.

1. Check that the function switch is in the correct

position (“HEAT” or “COOL”).

2. There may be as much as 4-minute delay before

the system turns On – wait and check. (Compressor
protection delay.)

3. Check your circuit breakers and switches to ensure

there is power to the system.

4. Replace batteries.

5. Make sure your furnace blower door is

 closed properly.

6. If your non-heat pump system only uses 4-wires, be

sure the jumper wire is installed between the RC and
RH terminals.

7. Check the position of the System Selector switch:

Standard or Heat Pump.

1. Press the reset button once with a small pin and hold

for two seconds. Then reprogram.

1. Replace unit.

1. Replace unit.

®

© 2003 Hunter Fan Company

41640-01  07/01/03

Hunter Fan Company

2500 FRISCO AVENUE

MEMPHIS, TN  38114

Reviews: