17
inSTalling ThE ThErMoSTaT, ConT.
ConnECTing ThE WirES
1. Loosen, but do not remove, the terminal
screws.
note: a jumper wire has been provided,
connecting the rC and rh terminals for
systems that do not provide both an rh
and rC wire. if you have both an rh and rC
wire, remove this jumper. if you do not have
both an rh and rC wire, leave the jumper in
place.
2. Match and connect the wires from the wall
to the terminals as shown. Wires should be
inserted behind the black terminal shields.
Tighten each screw after the connection has
been made.
(The ends of any extra wires should be wrapped in
electrical tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the
wall to prevent interference.
G RC RH Y W
Jumper