background image

7

®

HEAT TEMP

2

Auto Recovery

Hunter’s Auto Recovery feature meets the ENERGY STAR

®

 guidelines for energy efficiency by

allowing the heating or cooling system to recover gradually from an energy-saving setpoint
temperature to a comfort setpoint temperature.

Auto Recovery calculates how early to turn your system back On, so that the room temperature is
already comfortable by the start of the comfort temperature program period. Auto Recovery
works in both Heat and Cool modes.

When the thermostat is in Auto Recovery mode, the display
will alternate “RECO” with time, and the program indica-
tor will flash.

Auto Recovery can be disabled by sliding the Recovery
switch on the circuit board to disable.

Auto Recovery will not operate if Permanent hold or Tem-
porary hold is in operation.

Auto Recovery can be canceled manually if
HOLD / RETURN is pressed during the recovery
process.

Auto Recovery will be canceled and change to Temporary
Manual Override mode if the setpoint is adjusted during
the recovery process.

Error Mode

If the thermostat is unable to control your system due to
an unexpected battery problem, the thermostat will enter
Error Mode. In this condition, the thermostat flashes
“Err” on the LCD display, and shuts off your system. To
correct this problem, replace the batteries with 2 new AA
alkaline batteries, even if you have recently replaced
them. Next, use a paper clip to press the RESET button
next to the keypad. You will need to reprogram your
thermostat and confirm normal operation.

If Error Mode returns, please call Hunter Technical support at 1-888-830-1326 for further infor-
mation.

Auto Cut Off

Your thermostat will automatically cut-off in Heat mode if the room temperature rises above 95˚F
(35˚C). It will cut-off in Cool mode if the room temperature drops below 40˚F (4˚C).

Note that if your system has malfunctioned and no longer responds to thermostat controls, the
Auto Cut-Off will have no effect.

TROUBLESHOOTING

If you experience any other problems, call 1-888-830-1326 from 8 AM to 5 PM Central Time for
technical assistance.

®

© 2003 Hunter Fan Company

41638-01  06/30/03

Hunter Fan Company

2500 FRISCO AVENUE

MEMPHIS, TN  38114

Problem

No Display

Entire Display Dims

Program Does Not Change
at your Desired Setting

Auto Fan Does Not Turn
On Properly

Heating or Cooling Does
Not Go On or Off

Erratic Display

If unit continues to operate
in the Off position

Thermostat permanently
reads “HI”, “LO”, or “ERR”

Solution

1. Check battery connections and batteries.

2. Press RESET button with a small pin and hold in for

two seconds.

1. Replace Batteries

1. Check that the time is set properly to “AM”

or “PM”.

2. Check that the thermostat is not in Permanent

HOLD mode.

3. Check for the correct day setting.

1. Move HG/HE selector to correct position.

1. Check that the function switch is in the correct

position (“HEAT” or “COOL”).

2. There may be as much as 4-minute delay before the

system turns On - wait and check. (Compressor
protection delay.)

3. Check your circuit breakers and switches to ensure

there is power to the system.

4. Replace batteries.

5. Make sure your furnace blower door is closed

properly.

6. If your system only uses 4-wires, be sure the jumper

wire is installed between the RC and RH terminals.

1. Press the reset button once with a small pin and

hold for two seconds. Then reprogram.

1. Replace unit.

1. Replace unit.

Summary of Contents for 44110

Page 1: ...Model 44110 Programmable Thermostat Owners Manual M AM 4 TEMP ...

Page 2: ... System Switch Selector switch for Heat Cool and Off Fan Switch Fan switch forAutomatic or Continuous fan operation Battery Compartment Front access allows easy insertion of two AA 1 5V batteries Reset Press with a paper clip to reset the thermostat and return to power up settings Front Door Covers keys when not used for neat appearance Open by lifting from the bottom Up and Down Keys Keys for cha...

Page 3: ...wall pulling wires through large opening Insert mounting screws provided into wall anchor and tighten See Figure 3 NOTE 5 wire Systems If your thermostat has one wire marked R or RH 2 3 or 4 wire system then leave the jumper wire between the RH and RC terminals on the wallplate Otherwise if you have separate RH and RC wires 5 wire system then remove the jumper wire between the RH and RC terminals ...

Page 4: ...HE position is for certain electric systems having a fan relay Auto Recovery selector DISABLE ENABLE Your thermostat is set from the factory with the Auto Recovery Feature enabled which com plies with the EPA ENERGY STAR Program If you prefer to use normal recovery slide the switch to the DISABLE position Figure 7 F C Selection Fahrenheit Celcius Your thermostat is set for F mode from the factory ...

Page 5: ... Time Time Friday Temp Temp Temp Temp Saturday Time Time Time Time Sunday Temp Temp Temp Temp day time M PM SA PM 2 TEMP day time hold return or Revising Programs Familiarize yourself with manually changing programs so that you can easily modify the programs as your comfort needs change Follow the steps below to change the program times and temperatures NOTE 1 The program time can be set in 10 min...

Page 6: ... cooling system has been in use To maximize your system s performance and energy efficiency change or clean your filter regularly When the total system runtime for heat and cool reaches 400 hours the Filter Change Indicator will flash as a reminder to check your system s filter After changing or cleaning the system s filter press and hold the Filter Key for 3 seconds The display will blink and the...

Page 7: ...t at 1 888 830 1326 for further infor mation Auto Cut Off Your thermostat will automatically cut off in Heat mode if the room temperature rises above 95 F 35 C It will cut off in Cool mode if the room temperature drops below 40 F 4 C Note that if your system has malfunctioned and no longer responds to thermostat controls the Auto Cut Off will have no effect TROUBLESHOOTING If you experience any ot...

Reviews: