Hunter 42935-0 Installation Manual Download Page 12

42935-0  06/04/2007

2

Go to 

Section E -

Final Installation 

 on page 14.

 

Section D - Existing Construction – accessible from below

Remove one of the wiring access slugs on the top of the 

housing. Use a second wiring access plug if needed. 

EXISTING FAN

D3

Remove an existing fan and check to make sure the 

opening is large enough to accommodate the new fan 

housing. If there is no existing fan choose an appropriate 

location to make an ” x 9 5/8” opening.

Remove the mounting rail brackets.

3”

D4

Run the power supply wire through the strain relief, leaving 
3” between the end of the wire and the strain relief. Tighten 

the strain relief around the wire. 

D1

D2

Summary of Contents for 42935-0

Page 1: ...42935 01 06 04 2007 I n s t a l l a t i o n G u i d e Energy Star Bath Fan Models 82030 82031 82032 READ and SAVE THESE INSTRUCTIONS ENGLISH See page 2 Espa ol Vea la p gina 19...

Page 2: ...jury to persons SAVE THESE INSTRUCTIONS 2 Before installing servicing or cleaning the unit disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch locatio...

Page 3: ...cessary when any is used by or near children or invalids and when ever the is left operating and unattended 12 To avoid motor bearing damage and noisy unbalanced blower wheel keep drywall spray constr...

Page 4: ...If damaged call 1 888 830 1326 for replacement x4 E Mounting Screws Fan Mounting Screws NOTE Strain relief not supplied cable connector must be installed Attachment Screws 97934 01 262 97118 03 000 97...

Page 5: ...over D E C Choose Installation Option For New Construction attaching to joist go to step A1 page 5 For New Construction suspended between joists go to step B1 page 7 For Existing Construction accessib...

Page 6: ...edge of the joist based upon the the thickness of your sheetrock 5 8 1 2 5 8 1 2 A2 Pop out a wiring access slug OR Install the wiring and the strain relief into the wiring access hole you made earlie...

Page 7: ...Go to Section E Final Installation on page 14 Section B New Construction suspended between joists Pop out a wiring access slug B1 OR Slide the mounting rails into brackets Note the orienta tion of of...

Page 8: ...1 16 bit B5 Insert mounting screws leaving space between the screw head and the joist Screws are supplied Attach the rails onto the screws B6 B7 B8 Tighten screws Run the power supply wire through the...

Page 9: ...tape to secure joints If ducting does not fit securely an adapter may need to be purchased Go to Section E Final Installation on page 14 11 9 C1 Remove an existing fan and check to make sure the openi...

Page 10: ...2 C4 Using the depth markings on the housing position the bottom edge of the housing so that it will be flush with the sheetrock Pop out a wiring access slug C6 C5 Mark position of screws by using ho...

Page 11: ...the power supply wire through the strain relief leav ing 3 between the end of the wire and the strain relief Tighten the strain relief around the wire C11 Install the wiring and the strain relief into...

Page 12: ...needed EXISTING FAN D3 Remove an existing fan and check to make sure the opening is large enough to accommodate the new fan housing If there is no existing fan choose an appropriate location to make...

Page 13: ...er may need to be purchased Install the wiring and the strain relief into the wiring access hole you made earlier Position the bottom edge of the housing flush with the sheetrock Move the housing into...

Page 14: ...unted to a joist the final installation procedure is the same whether the housing is mounted to a joist or suspended between joists E4 E5 Install the fan assembly by inserting the tabs as shown and pu...

Page 15: ...42935 01 06 04 2007 15 E7 E8 Install the bezel by inserting the wire clips into the tabs on the inside of the housing Complete E9 Restore power at the source...

Page 16: ...CLEAN THE BEZEL Carefully pull the bezel down Use water a mild detergent such as dishwashing liquid and a soft cloth to clean the bezel DO NOT use abrasive cloths steel wool pads or scouring powders...

Page 17: ...ARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RE SPECT TO ANY HUNTER FAN BATH FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE...

Page 18: ...42935 01 06 04 2007 18...