All wiring must be in accordance with national and local electrical 
codes and ANSI/NFPA 70-1999. If you are unfamiliar with wiring, 
use a qualified electrician.

Wall switches are not included. Select an acceptable general-use switch 
in accordance with national and local electrical codes.
4-1.  Before attempting installation, make sure the power is still off. 
4-2.  To connect the wires, hold the bare metal leads together and place 

a wire nut over them, then twist clockwise until tight. For all these 
connections use the wire nuts provided.

4-3.  Connect the bare or green ground wire (grounding) from the 

ceiling to the green ground wire (grounding) from the ceiling plate 
and the green ground wire from the fan.

4-4.  Connect the white wire (grounded) from the ceiling to the white 

wire (grounded) from the fan.

4-5.  Connect the remaining wires as follows:

    Dual Switch Wiring: 

• The black wire (ungrounded) from the ceiling to the black wire 

(ungrounded) from the fan

• The black/white wire (ungrounded) from the fan to the wire 

(ungrounded) for the wall switch

    Single Switch Wiring: 

• The black wire (ungrounded) from the ceiling to the black 

(ungrounded) and the black/white wire (ungrounded) from 
the fan 

 CAUTION:

  Be sure no bare wire or wire strands are visible after 

making connections.

4-6.  Turn the splices upward and push them carefully back through the 

ceiling plate into the outlet box. 

4-7.  Spread the wires apart, with the grounded wires on one side of 

the outlet box and the ungrounded wires on the other side of the 
outlet box.

Dual Switch Wiring

Single Switch Wiring

Wire 

Connector

4 • Wiring the Fan

Summary of Contents for 42653-01

Page 1: ...lso attach your receipt or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No ______________________________...

Page 2: ...avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit...

Page 3: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Page 4: ...endent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades...

Page 5: ...ll four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the...

Page 6: ...embled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the set screw from the adapter 3 5 Place the low...

Page 7: ...the green ground wire from the fan 4 4 Connect the white wire grounded from the ceiling to the white wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring The black...

Page 8: ...tall two canopy screws into the holes opposite the ceiling plate tabs 5 4 Partially install a canopy screw between the slots in the canopy When all the holes are properly aligned securely tighten all...

Page 9: ...e blade mounting screws are installed in the motor to secure shipping blocks 6 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second b...

Page 10: ...housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing...

Page 11: ...rrect connection could cause improper operation and damage to the product 7 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower sw...

Page 12: ...d the fan pull chain through the grommet hole in the side of the cover plate 7 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 7 12 Thread the ligh...

Page 13: ...m the lower switch housing 7 18 Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wire...

Page 14: ...ckwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 8 5 Parts of this fan including the blades and the grill have been treated with Hunt...

Page 15: ...bling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that...