Hunter 41897-01 Installating And Operation Manual Download Page 7

6

Hunter Fan Company 

41897-01 • 11/22/05

7

41897-01 • 11/22/05 

Hunter Fan Company

4 • Installing the Ceiling Plate

Step 4-2

Steps 4-3 – 4-5

For Angled Ceilings:

 Be sure to 

orient the ceiling plate so that the 
arrows printed on the ceiling plate are 
pointing towards the ceiling peak. 

Ceiling

 Plate

Isolator

4-1.  Drill two pilot holes into the wood support structure through the 

outermost holes in the outlet box. e pilot holes should be 9/64” 
in diameter.

4-2.  Your fan comes with four neoprene noise isolators (“Isolators”). 

Position the isolators between the ceiling plate and ceiling by 
inserting the raised areas on each isolator into the holes in the 
ceiling plate.

4-3.  read the lead wires from the outlet box down through the hole 

in the middle of the ceiling plate.

4-4.  Align the slotted holes in the ceiling plate with the pilot holes you 

drilled in the wood support structure. For proper alignment use 
slotted holes directly across from each other. 

   

Note:

 e isolators should be flush against the ceiling.

4-5.  Place a flat washer on each of the two 3” screws and pass the 

screws through the slotted holes in the ceiling plate into the pilot 
holes you drilled. 

    Tighten the screws into the 9/64” pilot holes; do not use lubricants 

on the screws. Do not over tighten.

Flat Washer

3” Screw

Summary of Contents for 41897-01

Page 1: ...41897 01 11 22 05...

Page 2: ...you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electric...

Page 3: ...d or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls Stan...

Page 4: ...pliers CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Check for any shipping damage to the motor or fan blades If one of the fan blades was damaged in shipment return...

Page 5: ...installed 2 3 threads will still be visible this is normal Securely retighten the set screw with a wrench or pliers CAUTION e adapter has a special coating on the threads Do not remove this coating t...

Page 6: ...not remove the downrod CAUTION Do not carry or lift fan by the canopy 3 4 Lower the pipe and twig assembly onto the spindle Tighten the set screws and the assembly screws on the twig clamp using the...

Page 7: ...plate and ceiling by inserting the raised areas on each isolator into the holes in the ceiling plate 4 3 read the lead wires from the outlet box down through the hole in the middle of the ceiling plat...

Page 8: ...y appear slightly loose after the screws are tightened is is normal 5 3 Remove the blade iron mounting screws from the motor Discard the shipping blocks and save the screws 5 4 Partially install one b...

Page 9: ...wire from the ceiling to the green ground wire from the ceiling plate and the green ground wire from the fan e white wire from the ceiling to the white wire from the fan e black wire from the ceiling...

Page 10: ...tially install the three canopy screws into the canopy one at a time Once all three screws are in tighten them 7 5 Using both hands push the canopy trim ring up to the top of the canopy e canopy trim...

Page 11: ...e narrow end of the keyhole slots 8 5 Install the remaining 6 32 x 3 8 screw into the light fixture Tighten all three screws firmly CAUTION Make sure the light fixture is securely attached Failure to...

Page 12: ...m weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing...

Page 13: ...ping bumpers Problem Noisy operation 1 Tighten the blade bracket screws until snug 2 Tighten the blade screws until snug 3 Check to see if the blade is cracked If so replace all the blades 4 Be sure t...