Hunter 37205 Manual Download Page 5

42999-01  06/07/2006 

         

                                              ©  2006  Hunter  Fan  Company

5

operating Your humidifier

Functional Buttons

There are 6 buttons to control the functions of 

the humidifier. You will hear a confirmation ‘beep’ 

when a button is pressed.

1. 

PoWeR

 – Press the POWER button 

to set the humidifier to HI. Press the 

POWER button again to turn the unit 

OFF. 

a. 

When initially turned ON after being 

plugged in, the humidifier will ‘beep’ 

and all icons on the screen will be 

temporarily illuminated. After a few 

seconds, the LCD icons will turn OFF, 

and the unit will be in standby mode 

with the backlight OFF. 

b. 

Pressing POWER once will set the unit 

to HI and turn the backlight ON. The 

LCD screen will display the Continue 

message (“CO %") which means the 

unit will be continuously on HI until 

set otherwise. After a few seconds, the 

current room humidity and the ROOM 

message will be displayed. 

c. 

If the unit is plugged in and has been 

turned ON once, turning the unit OFF 

and back ON will display the Relative 

Humidity (RH) value last used. 

d. 

When the unit is ON, all backlights will 

remain ON. 

SeTTInG

 – The humidifier has two 

settings: HI and LOW. Press the SETTING 

button and the unit will loop settings 

(HI-LOW-HI) while the respective icon is 

illuminated. 

3. 

uP 

– Each time the UP button is 

pressed, the RH value will increase  

by 5 %. 

4. 

doWn

 – Each time the DOWN button  

is pressed, the RH value will decrease 

by 5 %. 

5. 

ReSeT

 – When the water level is too 

low, the unit will turn itself OFF. Pressing 

the RESET button will reactivate the unit 

after you have refilled the tank. 

6. 

nITe GLo™

 – Press the NITE GLO 

button to turn the blue night light  

ON or OFF.

UP

DOWN

SETTING

RESET

POWER

LIGHT

ENGLISH

42999_EngFr_WM Dig Humid.indd   5

6/7/06   1:25:22 PM

Summary of Contents for 37205

Page 1: ...1 06 07 2006 2006 Hunter Fan Company www hunterfan com The Care Free Warm Mist Humidifier Models 37205 37207 FRAN AIS Consulter la page 15 ENGLISH See page 1 42999_EngFr_WM Dig Humid indd 1 6 7 06 1 2...

Page 2: ...ier when it is not in operation or while it is being cleaned 6 DO NOT tilt or move the humidifier while it is in operation Never move the humidifier while there is water in the tank Empty the water ta...

Page 3: ...fect these parts NOTE The antimicrobial properties built into this humidifier do not extend to the water How The Care Free Warm Mist Humidifier Works humidified air or users Conduct routine cleaning a...

Page 4: ...er NOTE When the Water Tank is empty the refill indicator icon will turn ON and the unit will stop You must press the RESET button after refilling the Water Tank to reactivate the unit 5 Replace the T...

Page 5: ...I until set otherwise After a few seconds the current room humidity and the ROOM message will be displayed c If the unit is plugged in and has been turned ON once turning the unit OFF and back ON will...

Page 6: ...ity Set Range Humidity may be set between 40 RH and 85 RH in increments of 5 If the humidity is set higher than 85 the LCD screen will display the CO RH message indicating the humidifier is set to wor...

Page 7: ...perly seated before screwing it back onto the tank to ensure a proper seal 6 Place the Water Tank back onto the Base Make sure the Water Tank is properly seated on the Base or the humidifier will not...

Page 8: ...t performance NOTE The Water Tank Tank Cap Medicine Cup Boiler Cover Boiling Chamber and Exhaust Grille are dishwasher safe in the top rack only 1 Push the POWER button to turn the unit OFF the indica...

Page 9: ...of one 1 cup of white vinegar and one 1 gallon of clean water Fill the Water Tank with the solution and allow it to soak for 20 minutes occasionally swishing the solution to wet all interior surfaces...

Page 10: ...gged in 2 Check the circuit breaker or fuses 3 Adjust the humidity level using the UP or DOWN buttons Once the room reaches the set humidity level the humidifier will turn OFF this is normal 4 Check t...

Page 11: ...chsupport hunterfan com Please be prepared to tell the operator the model number of your humidifier the name of the part you need to replace and the part number Model Number Boiler Cover Exhaust Grill...

Page 12: ...THE ORIGINAL RESIDENTIAL USER OF CONSUMER PURCHASER CEASES TO OWN THE HUMIDIFIER THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTY OF ME...

Page 13: ...T INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE HUMIDIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANAD...

Page 14: ...ts from Hunter Hunter Original QuietFlo HEPA Air Purifier Programmable Thermostat To learn more about Hunter Fan products visit our web page at www hunterfan com HUNTER FAN COMPANY 2500 FRISCO AVENUE...

Reviews: