9
©2012 Hunter Fan Co.
44131-01 20121005
Figure 13.
5. Lift the UVC Bulb Carrier out of the unit. Figure 12.
6. Unscrew the UVC bulb from the carrier and dispose
of the UVC bulb in accordance with local or state
guidelines as trace amounts of mercury are present.
7. Partially remove the new UVC bulb from its packaging.
Be careful not to let the bulb come in contact with your
skin.
Note:
Oils from your skin can cause damage to the bulb
and will prevent it from working.
8. To prevent skin contact with the bulb, use the bag in
which the bulb was packaged to screw the bulb into
the carrier socket. Figure 13. Do not over tighten.
Discard the bag.
9. Reinsert the bulb carrier into the unit at a 45
o
angle
and turn clockwise to lock into the Air Purifier.
Note:
If the UVC Bulb door is not re-installed correctly,
the unit will not run.
10. Reattach the UVC cover by inserting the back tabs
into the Air Purifier and snapping the tab back into
place. Figure 14.
11. Reinstall the two screws that secure the UVC Cover.
Refer to Figure 9.
Figure 14.
Tabs
Cleaning the Unit
Clean the outside of the unit with a soft, damp cloth.
The rear grill can be cleaned in soapy water after it has
been removed from the unit and the Pre-Filter has been
removed.
Note
: Ensure the grill is completely dry before reinstalling
it on the unit. Failure to do so could cause damage to the
filters or motor.
Figure 12.