background image

FORM NO. 41068-01  8/95

- 1 -

©1995 HUNTER FAN CO.

CAUTION:

1. Read entire instructions carefully before beginning instal-

lation.

2. To avoid possible electrical shock, be certain electricity is shut

off at main panel before wiring.

3. All wiring must be in accordance with national and local elec-

trical codes. If you are unfamiliar with wiring, you should use
a qualified electrician.

WARNING:

1. To reduce the risk of fire or electrical shock, do not use a solid

state speed control with this fan. Use Hunter Controls only.

2. To reduce the risk of personal injury, do not bend the blade

brackets when installing the brackets, balancing the blades
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.

Step 1: Pre-Installation Instructions
A.

 Select installation site. Check to make sure that in normal use

no object can come in contact with the rotating fan blades. The
mounting site should also meet the precautions listed in Step 3
below.

B.

 Installation hardware is included for a standard drywall or plas-

ter ceiling. You will need a 4" x 1-1/2" or 4" x 1/2" octagon outlet
box and wire nuts (3) which can be purchased from any hardware
store or electrical supply house.

C.

 The fan blades must be mounted at least 7' above the floor.

For maximum efficiency, they should not have any obstruction
(walls, posts, etc.) within 24" of the blade tips. See Figure 1
for mounting distances.

Step 2: Inspection of Fan
A.

 Unpack unit carefully to avoid any damage to the components.

B.

 Check for any shipping damage to the motor and the fan blades.

If more than one fan is being installed, keep the matched and bal-
anced fan blades in sets, as they were shipped. Should one of the
fan blades become damaged during shipment, return all blades in
the set for replacement.

C.

 Check contents to be certain it contains a bag of parts.

INSTALLATION INSTRUCTIONS

FOR HUNTER LOW PROFILE CEILING FANS

READ AND SAVE THESE INSTRUCTIONS

8” MIN.

CEILING TO

FLOOR

7’ MIN.

TO FLOOR

CLEARANCE TO

OBSTRUCTIONS

24”

Step 3: Installation of Outlet Box and
Rough-In Wiring

CAUTION: Your Hunter ceiling fan with accessories can weigh
up to 35 lbs. The following precautions must be taken for safety
and to ensure that your fan is securely mounted to the ceiling.
• Be certain electricity is “off” at the fuse panel when inspecting

or repairing installation site.

• All wiring must meet local and national electrical codes.
• Do not mount directly to an unsupported ceiling or to an elec-

trical outlet box. Mounting must support a 35 lb. fan with ac-
cessories.

A.

 Secure a metallic outlet box 4" x 1-1/2" or 4" x 1/2" deep to 2 x 4

cross brace between two ceiling joists as shown inFigure 2. The
outlet box must be recessed in the ceiling by 1/16" minimum. Se-
cure the outlet box to the cross brace by drilling (2) pilot holes no
larger than the minor diameter of the woodscrews (5/64") and use
two #8 x 1-1/2" woodscrews and washers. Use the innermost holes
for securing the box. Orient the box so the outermost holes are aligned
with the 2 x 4 brace. The outermost holes will be used in Step 4B.

CAUTION: Do not use a lubricant on screws.

FIGURE 1

FIGURE 2

CEILING JOIST

2 x 4 WOOD BRACE

CEILING

OUTLET BOX

#8 WOODSCREW &
WASHER (2) REQUIRED

B.

 Bring electrical cable into the outlet box and attach with an

approved connector. Make certain that wiring meets all national
and local electrical codes. Wire leads should extend at least 6"
beyond outlet box for ease in making connections. See Figure 3.

CONNECTOR

6” MIN. LEAD LENGTH

FIGURE 3

Summary of Contents for 20808

Page 1: ...s as they were shipped Should one of the fan blades become damaged during shipment return all blades in the set for replacement C Check contents to be certain it contains a bag of parts INSTALLATION INSTRUCTIONS FOR HUNTER LOW PROFILE CEILING FANS READ AND SAVE THESE INSTRUCTIONS 8 MIN CEILING TO FLOOR 7 MIN TO FLOOR CLEARANCE TO OBSTRUCTIONS 24 Step 3 Installation of Outlet Box and Rough In Wirin...

Page 2: ...LET BOX 2 x 4 BRACE HANGER BRACKET CEILING PLATE FLAT WASHER MOUNTING SCREWS FIGURE 5A FIGURE 5 Step 5 Hanging of Motor CAUTION Do not lift motor by wires A Lift the motor and insert the plastic hanger into the opening in the front of the hanger bracket See Figure 5 Make sure none of the wires are trapped between the plastic hanger and the inside of the hanger bracket B Rotate the motor and plasti...

Page 3: ...ing when the blades are assembled FIGURE 6 FIGURE 6A Check and make sure all wiring is tucked up into the outlet box LOCKING SCREWS B Place the fan housing over the motor assembly and fasten the housing to the ceiling plate using the four screws provided two each side See Figure 6A ASSEMBLY SCREWS FAN HOUSING Check and make sure the motor clears the opening in the bottom of the housing Step 8 Fan ...

Page 4: ...w If you wish to change direction switch fan off and allow to stop Slide reversing switch to the opposite position and switch fan back on See Figure 8 Speed Control As an option a wall mounted speed control switch is available from your Hunter dealer HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 1995 HUNTER FAN CO FORM NO 41068 01 8 95 4 1 Turn power on or replace fuse 2 Check all wire co...

Reviews: