5.2.7 Door Sensor Detection Time
Command Code 11.
Applicable only if door sensor is installed. Default value is 0 which
means this function is deactivated. Sensor detection time may be set from 1
~
600.00 sec.
(System ignores value greater than 600 sec.)
When door sensor detection time has been set, system will monitor door’s status. If the
allotted door open time has expired, controller beeps every 0.5 sec. The door has to be
closed for the controller to terminate its alarm. However, if door was forced open,
controller will activate the Alarm Relay to alert the administrator or security personnel. To
deactivate the Alarm Relay, input the disarm code(Default is 0000).
Enter 11
Detection Time
Master Card/Code
(Default 30191000)
Completed
Unit is
0.01Sec.