5.2.23 Set Memory Mode
Command Code 93
Allows user to change the memory mode. There are three different
types of memory which are standard, compressed and shared.
i.
Standard memory : supports 1024 card nos. with password and 800 event
records.
ii.
Compressed memory : supports 1400 compressed card nos. with password and
1800 event records.
iii.
Shared memory : supports 65536 card nos. without password and 1800 event
records.
1. Under compressed and shared memory mode, card number should be exactly 10
digits.
2. Successive addition and deletion of card number can only be performed under
shared memory mode. This function is not applicable for compressed and
standard mode.