Operation
Control Panel
An On-Off rocker switch on the back right side of the machine is
the power switch. The control panel is situated on the front left
hand side of the machine base. A 7" touch-screen displays the
speed and units in either in/min or mm/min. A touch-screen en-
ables setting the speeds and units and control of machine travel.
Speed Selection
On the control panel, pressing Motor Speed causes the display to
display the motor speed keypad where you can enter the desired
speed.
Speed Units Selection
Press the unit to select in/min or mm/min.
Running a Test
After selecting the desired speed and positioning the sample, ini-
tiate a test by pressing the Up Arrow. Upon conclusion of the test
press the Stop Test key. See Page 7 for a chart of common tests
and test speeds.
Rapid Travel
Pressing and holding down either the up or down arrows allows
travel at slightly over 2.25 in/min in the direction chosen and
releasing either key will stop the travel.
1