22
LNX-204 (Ver.1.1)
8.
Controller Command
You can control with simple single character command shown in the following table
by using terminal software and keyboard. Each controller command is an ASCII
text. The command is case sensitive.
Send Command
Function
Response
‘1’
~
‘4’
Select LAN port from 1 to 4
<CMD>,[active channel]<CR>
‘0’
Select no LAN port
<CMD>,0<CR>
‘C’
Get active LAN port
<CMD>,[active channel]<CR>
‘V’
Get product version
“LNX-204 Ver.***”<CR>
other
-
“Undefined command”<CR>
<CMD> : response sending command
<CR> : Carriage Return (0x0D)
9.
Virtual COM Port
You can use the software that creates Virtual COM ports on your PC. You can use
the COM port to communicate to an IP address of LNX-204.
Please refer to the "LNX series virtual COM port User's Manual" that are stored on
the product supplied CD for details.