background image

 

21 

 

LNX-003(Ver.1.0) 

 

8.3.

 

Write Setting Data 

1.

 

Open Setting Tool for LNX series (LNX SETTING TOOL Ver*.*). 

2.

 

Select “LNX-003/LNX-003e LAN to RS485/422 Converter”, and click “OK”.

 

 

3.

 

Enter the setting such as network or serial. 

4.

 

Insert a microSD card to PC (A USB adapter is included with the product) 

5.

 

Click “Save data”.

 

 

Summary of Contents for LNX-003

Page 1: ...HuMANDATA LTD RS 485 422 LAN Converter LNX 003 Rev2 User s Manual Ver 1 0...

Page 2: ......

Page 3: ...5 2 wire 10 5 Interface Terminal 10 6 Setting Switch 11 6 1 RS 485 422 4 wire Mode 11 6 2 RS 485 2 wire Mode 12 6 3 Setting Switch SW2 Function 12 7 Connection examples 13 8 Setting Tool 14 8 1 Access...

Page 4: ......

Page 5: ...owing to improvements 7 All efforts have been made to produce the best manual possible but if users notice an error or other problem we ask that they notify us 8 Item 7 notwithstanding HuMANDATA cann...

Page 6: ...es it possible to use RS 485 422 devices via Ethernet local area network LNX 003 has obtained the CE marking except for PoE function 1 Product Configuration The following lists the product configurati...

Page 7: ...001 USB to LAN converter or LNX 003 In that case connecting with devices in other RS 485 422 network is possible And by using TCP UDP or Telnet direct control from PC is also available LNX 003 support...

Page 8: ...Name color Function ACT Active LED green Turn on during network port communication LINK Link LED yellow Turn on when LNX 003 is powered and LAN cable is connected normally Terminal Block Setting SW1 A...

Page 9: ...process Turn on when system is ready POW Power LED red Turn on when the power is supplied to the LNX 003 TX Transmission LED red Turn on when data are transmited to RS485 422 side RX Reception LED re...

Page 10: ...rotection 11KV isolation over 1500Vrms Protocol TCP UDP Telnet ESD protection 15KV Interface RS485 422 2 wire or 4 wire isolated from inner circuit DC3000V 5 08mm pitch Connector 5 position Terminal B...

Page 11: ...rts and specifications are changed Power saving function suspend standby sleep and others is not supported Please use the microSD card that comes with the product 4 2 AC adapter Item Description Remar...

Page 12: ...5 2006 Surge immunity test requirements EN61000 4 6 2009 Conducted radio frequency requirements EMI EN61000 6 4 EN61000 6 4 2007 A1 2011 Radiated Emissions EN61000 6 4 2007 A1 2011 Conducted Emission...

Page 13: ...on Baud Rate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 bps Number of Connectable Terminals 128 Typical example Termination Resistor 120 Configurable by setting switch SW1 ON OFF Tran...

Page 14: ...r 120 Configurable by setting switch SW1 ON OFF Transmit Receive Switching Automatically controlled Echo Cancellation Available by setting switch SW2 RS 485 mode can communicate with multiple terminal...

Page 15: ...ing 6 1 RS 485 422 4 wire Mode SW2 Default Setting 1 2 4 wire OFF ON Please refer to Section 6 3 SW1 1 2 3 4 No termination OFF OFF OFF OFF SW1 1 2 3 4 Transmit Side termination OFF OFF OFF ON SW1 1 2...

Page 16: ...4 No termination OFF ON ON OFF SW1 1 2 3 4 Termination Enable ON ON ON OFF Disable the echo cancelling SW2 1 2 RS 485 ON ON 6 3 Setting Switch SW2 Function SW2 1 DE transmit enable Control OFF Always...

Page 17: ...tween LNX 001 and LNX 003 LNX 001 offers you to control as USB interface via the LAN By connecting this with LNX 003 in tunneling mode virtual COM port and D2XX API by FTDI is available Technical know...

Page 18: ...14 LNX 003 Ver 1 0 8 Setting Tool Setting tool supports data saving and reading using microSD card This tool does not require installation This is a screenshot from version 1 7...

Page 19: ...off PowerON Detect Ready microSD card None Settingdata WR_DATA TXT Find None Producttype Verify OK NG TX RXLED flicker Differentproducttypesinthe setting dataand actual product Itis necessarytocorrect...

Page 20: ...d Saving data Read setting data RD_DATA txt to microSD card Network Read or write setting data over the network LNX product and PC must be connected to the same network segment Product select Display...

Page 21: ...ddress or router allows communication to other LAN segments The gateway address should be the IP address of the router connected to the same LAN segment as the unit The gateway address must be within...

Page 22: ...the remote port number for tunneling target Connection method Select connection method to the target Baudrate LNX 003 and attached serial device must agree on a speed or baud rate to use for the seri...

Page 23: ...ket count low The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network WAN Adjusting parameters in this mode can...

Page 24: ...nter a value between 0 and 60 seconds 0 disables keepalive The default setting is 5 Telnet Com port control RFC2217 Set to enable when control COM port using Telnet The product enable a RFC2217 functi...

Page 25: ...etting Tool for LNX series LNX SETTING TOOL Ver 2 Select LNX 003 LNX 003e LAN to RS485 422 Converter and click OK 3 Enter the setting such as network or serial 4 Insert a microSD card to PC A USB adap...

Page 26: ...nsert it to the product Please confirm that the product power is turned off 9 When the product is powered on the setting data is configured to it automatically After the data is stored in the product...

Page 27: ...ill be reserved to the microSD card automatically The data file name is RD_DATA TXT Please be careful not to detach the microSD card before TX RX LED is light off If there is the same file name in the...

Page 28: ...24 LNX 003 Ver 1 0 5 Click OK in the confirmation dialog 6 Open the RD_DATA TXT in the microSD card 7 Setting data is loaded...

Page 29: ...is not inserted in a product 2 Enter an IP address manually or click Search When some products are found please select a number from a list 3 Click Read data or Write data Even if some devices will b...

Page 30: ...IP Address 192 168 0 101 255 255 255 0 Subnet Mask 255 255 255 0 0 0 0 0 Default Gateway 0 0 0 0 10005 Port Number 10005 TCP Protocol TCP 192 168 0 101 Remote IP Address 192 168 0 100 10005 Remote Por...

Page 31: ...Setting 192 168 0 100 IP Address 255 255 255 0 Subnet Mask 0 0 0 0 Default Gateway 10005 Port Number TCP Protocol 0 0 0 0 Remote IP Address 0 Remote Port Number Serial Communication 230400 Baudrate RT...

Page 32: ...from its own serial port to the attached equipment Please refer to the LNX series virtual COM port User s Manual that are stored on the product supplied CD for details 10 Additional Documentation and...

Page 33: ...29 LNX 003 Ver 1 0...

Page 34: ...User s Manual Ver 1 0 Oct 25 2016 HuMANDATA LTD Address 1 2 10 2F Nakahozumi Ibaraki Osaka Japan ZIP 567 0034 Tel 81 72 620 2002 Japanese Fax 81 72 620 2003 Japanese English URL http www fa hdl co jp...

Reviews: