A service of all passages is necessary once a year. If you can do this yourself,
the following procedure is to be followed:
-
Unscrew and unmount all the control switches in the housing with the
small socket screw key (gears, exposure lever shaft, wedge caps, se-
lector switch shaft, …).
-
Remove the o-ring out of its groove. Use the control shaft or a non
metalic tool.
-
Wash axe and o-ring with soap (do not use degreasers), rinse with
fresh water and dry thoroughly or let it dry for a while.
-
Slightly grease with Hugyfot-grease.
-
Position the greased o-ring in its groove, gently slide the axe back in
and mount the control switch back to its proper position.
-
When the control switches are mounted you may mount the camera
into the housing. Now check all the controls on their proper function-
ing.
Always perform a pressure test after removing/installing control switches or
perform a testdive without camera inside the housing.