Chapter 6 • Troubleshooting
1037106-0001 Revision B.03-Draft
63
.
Fatal error indication
Follow these steps if the Power LED is off and one or more of the
other LEDs is blinking:
1. Power cycle the remote terminal by unplugging the power
cord from the power source, waiting 10 seconds, and then
plugging it back in. If the problem persists, continue with
step 2.
2. Disconnect the receive and transmit cables from the remote
terminal.
If any of the LEDs illuminate and remain on, continue with
step 3.
If the Power LED is still off and one or more of the other
LEDs continue to blink, skip to Step 4.
3. Replace the receive and transmit cables that connect the
antenna assembly to the remote terminal. If the problem
persists, continue with Step 4.
Figure 41: HX100 power and cable connections
J5-SERIAL SYNC/ASYNC
J3-LAN 1
J2-DEBUG
J1-TEL
J4-LAN 2
J6-SAT IN
J7-SAT OUT
J8-POWER
HX100
Transmit cable
LAN
2
Receive cable
Surge
protector
Power
cord
G-28580 C 05/31/06
Serial device
DCE serial cable
with 25-pin male
connector
Ethernet cables to
Ethernet devices
Summary of Contents for HX100
Page 12: ... Figures xii 1037106 0001 Revision B 03 Draft ...
Page 14: ... Tables xiv 1037106 0001 Revision B 03 Draft ...
Page 34: ...Chapter 2 Preparing for the Installation 16 1037106 0001 Revision B 03 Draft ...
Page 42: ...Chapter 3 Installing the Hardware 24 1037106 0001 Revision B 03 Draft ...
Page 60: ...Chapter 4 Commissioning the HX50 HX100 Remote Terminal 42 1037106 0001 Revision B 03 Draft ...
Page 68: ...Chapter 5 Completing the Installation 50 1037106 0001 Revision B 03 Draft ...
Page 86: ...Chapter 6 Troubleshooting 68 1037106 0001 Revision B 03 Draft ...
Page 106: ...Chapter 7 The System Control Center 88 1037106 0001 Revision B 03 Draft ...
Page 128: ...Appendix C Disabling a Web browser s proxy connection 110 1037106 0001 Revision B 03 Draft ...