Chapter 1 • Overview
1037749-0001 Revision B
5
Refer to the installation reference sheet for any customer-specific
guidelines concerning the mount installation. Use only the
installation method described in the reference sheet.
If the installation reference sheet does not specify a method, use
only the mount installation methods documented in the
HughesNet Antenna Site Preparation and Mount Installation
Guide (1035678-0001). Most installations in a commercial,
industrial, or institutional environment use a non-penetrating roof
mount.
Installing the IDU
See the installation guide for the specific IDU you are installing.
Grounding
The entire antenna assembly must be grounded. For grounding
information, refer to your training, best grounding practices, the
Hughes Field Service Bulletin (FSB) HNS Broadband
Requirements for RG-6 and RG-11 IFL Cable Connectors,
Ground Blocks and Ground Block Location
(FSB 050518_01), and applicable parts of the National Electrical
Code (NEC).
Approved cables
For a list of approved coaxial cable types for the IFL between the
antenna and the IDU, see the Hughes FSB, IFL Cable, Approved
List (with lengths) for SPACEWAY Domestic Installations (FSB
080202_01). The FSB lists the maximum cable length for each
approved cable type for all relevant radio types.
Because it is impossible to predict the requirements specific to
each installation site, you must use your own judgement and best
practices to determine how to route and connect the IFL transmit
and receive cables.
Summary of Contents for AN8-074P
Page 14: ... Tables xiv 1037749 0001 Revision B ...
Page 20: ...Chapter 1 Overview 6 1037749 0001 Revision B ...
Page 46: ...Chapter 3 Installing the antenna and radio assembly 32 1037749 0001 Revision B ...
Page 58: ...Chapter 5 Adjusting the antenna azimuth and elevation 44 1037749 0001 Revision B ...
Page 60: ... Acronyms and abbreviations 46 1037749 0001 Revision B ...