Page 12 of 28
Huge Systems U320-R User’s Guide
800007 rev C1
Wipe 6
This mode will start a write operation to
all the disk drives in the array. This is
used to completely wipe out any previous
configuration and settings.
Mfg
Test
7
This mode will over write data on the
HMV U320 as the diagnostic will perform
read and write tests on every drive and on
every block of data. The unit records
vital parameters of each disk drive’s
performance, and it can be retrieved using
the Diagnostic Port for further analysis.
*Make sure to “Double Beep” to set the mode.
Double Beep
As a precautionary measure to protect from un-intentional mode changes. A combination of holding down
the Mode Set Button and turning the unit on must be performed to cause the change.
1) Turn off the computer.
2) Determine the Mode desired and note the Mode Selection value.
3) Set the value on the Mode Selection switch. Use a pointed instrument and press the tiny button
above or below the number window.
4) Turn the power off to the U320-R unit.
5) Press and hold the Mode Set Button.
6) Apply power to the U320-R.
7) Within about 20 seconds you will hear two beeps to confirm the change.
8) Release the Mode Set Button.
9) Turn the computer on.