Incremental Encoder FG 2
FG2_MANUAL-en_R8(2016-08-11)ID70199.doc
19
6.
Connect the supply voltage, the signal cable and possibly option S (please refer to the
connection diagrams, Chapter 14).
CAUTION!
Do not apply supply voltage to the signal outputs, as this will destroy the device!
7.
Close the terminal box cover.
NOTES!
Before closing the terminal box cover check and if necessary clean both seal surfaces
and the gasket.
CAUTION!
Ensure when closing the terminal box cover that no cable becomes jammed.
For encoders with option S only:
1.
Remove the blind plug from inside of the housing
2.
Remove the cable gland
3.
Close the opening with the blind plug
7
Dismantling
7.1
Safety instructions
Personnel
Dismantling must be carried out by skilled technical staff only.
WARNING!
Observe the safety instructions contained in
Chapter 2
when dismantling the device!
NOTES!
Do not use a hammer or similar tool when dismantling the device due to the risk of
damage occurring to the bearings or coupling!
7.2
Dismantling the encoder
Disconnect all electrical cable prior to beginning any work.
To dismantling the encoder follow the instructions given in Chapter 6.5 in the reverse order.