Hubert HUBM-23FB Service, Installation And Operation Manual Download Page 10

SWING DOOR REPLACEMENT AND ADJUSTMENT  

1   Open the bottom shroud and hold the door, then loosen the bottom hinge’s screws and take off 

the old door     

2   Prepare new door, insert top pin into top hinge, get one bottom hinge to hold the door by the 

bottom pin, then fasten bottom hinge securely to the door frame with three screws;

3  Allow the door to freely swing, make sure it swings closed by itself with no restriction 
4  Plug the unit in and make sure the lock works well;
5   If not, adjust the door height by adding the plastic spacer/washer provided to the bottom hinge pin 

SLIDING DOOR REPLACEMENT AND ADJUSTMENT

1  Take off the hook of counterweight of door from top of the door;
2   Hold the door up until it’s bottom edge is over the bottom channel, move the door out across the 

channel and lay the door down;

3   Prepare new door, hold the door insert into top channel until bottom edge is over the bottom 

channel, move bottom of door across the channel wall and set it down in to the channel 

REMOVE THE BOTTOM SHROUD 

Loosen and remove the top screws, slide the shroud up and out 

LIGHT BULB REPLACEMENT

1   Upper light bulb replacement: Loosen the screws in the bottom of top shroud, swing the top shroud 

up until it is held by the top of the cabinet, now the light bulb can be replaced 

2  LED light bulb replacement: Take the cover off, then the LED bulb can be replaced 

9

Summary of Contents for HUBM-23FB

Page 1: ...073015 Service Installation and Instructional Manual Glass Door Merchandiser Refrigeration and Freezer HUBM 23RB FB HUBM 48RB FB HUBM 72RB FB PLEASE READ CAREFULLY...

Page 2: ...taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported...

Page 3: ...20 60 1 7 48 1 2 18 7 540 5 15P HUBM 72RB 120 60 1 10 72 3 4 21 2 741 5 15P SWING GLASS DOOR FREEZERS Model Number V Hz Ph AMPS STORAGE CAPACITY Cu ft HP CHARGE OZ SHIPPING WEIGHT LBS NEMA PLUG HUBM 2...

Page 4: ...nit Should it become necessary to lay the unit on its side or back for any reason allow at least 24 hours before start up so as to allow compressor oil to flow back to the sump Failure to meet this re...

Page 5: ...ns will run at any time when the evaporator coil temperature is below 35 F and they will cycle off during defrost period Every 6 hours the unit will shut off and the defrost heater will defrost the ev...

Page 6: ...y value To see the last temperature alarm in programming mode it browses the parameter codes or decreases the display value KEY COMBINATION To lock unlock the keyboard To enter programming mode To ret...

Page 7: ...le only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3 seconds the POF message will be displayed 2 5 HOW TO UNLOCK THE KEYBOARD Keep pressed the and keys t...

Page 8: ...peratures and excessive run times continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures will void any warrantie...

Page 9: ...er use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized ser...

Page 10: ...R REPLACEMENT AND ADJUSTMENT 1 Take off the hook of counterweight of door from top of the door 2 Hold the door up until it s bottom edge is over the bottom channel move the door out across the channel...

Page 11: ...SERVICE AND INSTALLATION MANUAL www hubert com NOTES 10...

Page 12: ...800 543 7374 www hubert com...

Reviews: