![Hubert 53232 Technical Bulletin Download Page 6](http://html1.mh-extra.com/html/hubert/53232/53232_technical-bulletin_2180831006.webp)
9555 Dry Fork Rd., Harrison, OH 45030-1994 • 1-800-543-7374 • www.hubert.com
6
Hubert #53232
U.L. Listed
testing
Testing the Cut-Off Rod:
1. Disconnect the “red” CUT-OFF ROD wire from terminals 1 and 2.
2. Using an ohmmeter, measure the resistance across “red” terminal wires.
3. Disconnect “black” sensor wires from terminals 5 and 6. If the reading across “black” sensor wires is over
1M Ohms or if there is no reading -replace Cut-Off Rod.
Testing the Circuit Board:
1. Disconnect rod wires from Circuit Board. (Terminals 1, 2, 5 and 6).
2. Using D.C. voltmeter and with the switch “on”: the reading across “black” sensor terminals should be 6.5 VDC.
If it is less, replace Circuit Board.
3. Reconnect ”black” wires to board. Reading should be 3 VDC. If less than 3 VDC- replace Circuit Board.