INSTALLATION MANUAL

MASTERLINE Ultimate Small Cell

Page 4 of 4

HUBER+SUHNER disclaims any liability resulting from incorrect installation and use, including any damages resulting from the use of tools and

accessories other than the ones recommended herein. Any installation performed by unqualified personnel voids the product warranty provided by

HUBER+SUHNER. All due care and attention must be exercised when performing the installation of these products. For advice concerning the gen-

eral handling of these products please contact HUBER+SUHNER.

Step 6:

Connect the Small Cell housing to the RRH
using jumper cables.
The connectors can be engaged in the ports
provided by applying gentle pressure. Turn it
gently in the opposite direction to check that
the connector is properly engaged.
Please refer to the general instructions in the
user manual for guidance on handling cables
and laying multi-connector cables.

Step 7:

All jumper cables must be fastened at regular
intervals of not more than 1 meter using cable
clamps.

Step 8:

Once all the jumper cables have been con-
nected, the main line can be connected to the
base station or to the fiber-optic cable.
The protective tube must be removed before
connecting.
When untwisting the protective tube, ensure
that the cable is not twisted around its own
axis.

Step 9:

Connect the Small Cell housing to the base
station using suitable cables.
The connectors can be engaged in the ports
provided by applying gentle pressure. Turn it
gently in the opposite direction to check that
the connector is properly engaged.
Please refer to the general instructions in the
user manual for guidance on handling cables
and laying multi-connector cables.

Summary of Contents for MASTERLINE Ultimate Small Cell

Page 1: ...HUBER SUHNER declines all liability and claims if the specifications are not met NOTES IN THIS MANUAL The following symbols are used in this manual Info notes Info notes contain important instructions for installation and proper use of the product throughout its life cycle The info notes also indicate that non compliance may result in material damage or financial loss Notes about hazards and safet...

Page 2: ...please contact HUBER SUHNER INSTALLATION Step 1 Slinging points The Masterline Ultimate Small Cell may only be lifted up at the slinging points marked in red Avoid buckling the cable or bending it at less than the minimum radius while the device is being raised All plug type cables must be unplugged prior to raising Step 2 Fixing Mast mounting The Small Cell may only be fixed to a flat base by the...

Page 3: ...LU SC A1 and MLU SC H1 must be secured within 1 meter by means of a suitable cable clamp The offset between the first cable clamp and the cable entry must be kept to a minimum The cable must be fastened at regular inter vals of not more than 1 meter using a suitable cable clamp Step 4 In the case of a daisy chain installation all the Small Cell housings must be fastened in ac cordance with steps 1...

Page 4: ...to check that the connector is properly engaged Please refer to the general instructions in the user manual for guidance on handling cables and laying multi connector cables Step 7 All jumper cables must be fastened at regular intervals of not more than 1 meter using cable clamps Step 8 Once all the jumper cables have been con nected the main line can be connected to the base station or to the fib...

Reviews: