INSTALLATION INSTRUCTIONS - SGF2 OR SGF3 SLING FLOODLIGHT
SAVE THESE INSTRUCTIONS
READ THOROUGHLY BEFORE INSTALLATION
93158107 Rev-A
Hubbell Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
Due to our continued efforts to improve our products, product specifications are subject to change without notice.
© 2021 Hubbell Lighting, All Rights Reserved • For more information visit our website: www.hubbelloutdoor.com
Mounting hardware not provided. See "trunnion
detail" for the holes that are provided. For aiming
remove the two "45 degree locking screws".
Loosen the two "screws for rotation locking". If
aiming in 45 degree increments is desired, holes
are provided for inserting the "45 degree locking
screws". Tighten the "screws for rotation locking".
(T) Trunnion Version
(K) Knuckle Version
Note: This mounting device is
designed to fit on a tenon or pipe
that is 2-3/8" (O.D) diameter maximum.
Trunnion Details
3.13
2.09
.886 HOLE
1-PLACE
.531 HOLE
2-PLACES
5.83
"45 DEGREE LOCKING SCREW"
USE 5mm HEX KEY
"SCREW FOR ROTATION LOCKING"
USE 8mm HEX KEY.
SCREW FOR ROTATION LOCKING.
USE 14mm HEX KEY
SCREWS TO TIGHTEN
ONTO TENON. 8-PLACES.
USE 6mm HEX KEY.
Knuckle Version: 8 screws are provided to
tighten onto your tenon. Once all have been
tightened, then loosen the "screw for rotation
locking". Aimthe fixture to the desired angle and
then tighten the "screw for rotation locking".