IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
Part No...........................................
93050908
Page 1 of 2
With representatives offices in principal cities throughout North America.
Copyright , revision, All Rights Reserved - Printed in U.S.A.
701 Millennium Blvd • Greenville, SC 29607
2018 06/29/18
w
w
w
.p
re
s
c
o
lit
e
.c
o
m
•
P
re
s
c
o
lit
e
T
o
ll
F
re
e
T
e
c
h
n
ic
a
l S
u
p
p
o
rt
1
.8
8
8
.P
R
S
.4
T
E
C
•
H
o
u
rs
: 8
a
m
-
5
p
m
E
T
In
s
tr
u
c
tio
n
S
h
e
e
t
INSTALLATION INSTRUCTIONS
LITEFRAME ® LC4, 4LC, LC6, 6LC, LC8, & 8LC
1.
Install the fixture in the ceiling using the hanger bars (supplied), or mounting channel or bars (by others) placed in the adjustable mounting
brackets.Mount the fixture in the ceiling so that the weight of the fixture is supported by the hanger bars, mounting channel, bar, and/or hanger wires
secured to the building structure.
2.
Adjust the fixture so the bottom of the plaster flange opening is flush with the finished ceiling line and in alignment with adjacent fixtures. Secure
mounting brackets by tightening wing nuts on either side of the fixture.
3.
Determine where the supply wiring conduit will enter the J-Box and attach it in conformance with the National Electric Code.
4.
Remove J-Box cover plate. Remove appropriate knockout and assemble the appropriate connector for the supply wire used. Connect ground wires to
green ground leads. Connect white (common) to white (leads). Connect power supply (line) to black lead(s). Reinstall J-Box cover.
WARNING: DO NOT pinch wires between J-Box/ballast cover and J-Box. Consult a qualified electrician for all other options that require
other wiring configurations.
5.
Pull the electrical cover (1) down through opening in fixture.
6.
Insert connector (5) into the connector (6) and snaps firmly together.
7.
Carefully put wires and connectors (5) & (6) into cover (1). Place tab (7) into slot of reflector (8) and screw (9) into hole in reflector (8). Make sure
there are not any wires pinched between item (1) and item (8). Tighten screw (9).
8.
Squeeze two torsion springs (10) together and insert ends into two brackets (11). Make sure hole in the reflector (8) lines up with the placement of the
EM switch (2). Loosen the nut (3) to adjust the position of EM Switch (2) in the bracket (4) to line up with reflector cutout (8) if required.
9.
Push trims assembly up towards the ceiling until the springs draw, trim firmly against the ceiling.
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE.
SAFETY AND PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.