P/N KIL00921398 FORM NO. K1398 R01/13 ECO-6-010-13
Sheet 4 of 4
Directions for Installation of KFL Accessories
KFL-DARK Reflector
IMPORTANT
- Before installing, check the fixture nameplate to be sure you have the correct fixture.
WARNING
- Turn OFF the supplying circuit before starting installation.
1) To install reflector, carefully remove the (7) screws provided in housing that align with the locations of the holes on the reflector and
retain the screws. Place the reflector into position, lining up the holes in the reflector with the holes on the lens housing. Reinstall the
removed (7) screws into the existing hole location, and tighten to secure.
CAUTION
—All screws must be properly installed to maintain
the integrity of the lens gasket seal.
KFLG Guard
2) To install lens assembly guard (KFLG), verify that the luminaire is completely assembled. Install lens guard on lens assembly by
hooking the guard’s end tabs under the luminaire housing’s end tabs. Verify a tight attachment.
3) Turn ON the supplying circuit and test the fixture.
NOTE
–
Reflector (KFL-DARK) and Guard (KFLG) cannot be used simultaneously.