Hubbell JTX011 Instruction Manual Download Page 2

WARM WATER IN

HOT WATER OUT

Drain Port

Dielectric Unions

Flow Meter

Inlet Thermistor

Numeric Digital Display

Senses inlet water temperature

Solid State Switches

Electronic Temperature Controller 

is adjustable from 32 - 194°F in 1° 

increments in either °F or °C

Modulate heating elements 0-100% 

to ensure accurate and consistent 

temperature and long element life 

Measures the exact flow rate which 

enables the control system to provide 

perfectly matched heating power with demand

Simplifies plumbing installation

Safety Thermostats

Auto resetting Hi-Limit thermostats 

protect against over heating

Outlet Thermistor

Provides feedback to ensure

consistent outlet temperature

Heating Chamber

All copper and bronze 

construction

Stainless Steel Exterior 

Sleek design and corrosion resistant 

for long life

Incoloy Sheathed for long life

Heating Elements

Commercial Quality

Simplifies maintenance

(Only Required on Models over 240 Volt)

Magnetic Contactor

(Only Required on 3 Phase Units)

Fully disengages the heating

elements in a fault condition

Step down transformer provides 

240 Volt control circuit power

Control Transformer

Power Distribution Block

Provides a heavy duty single point

power connection

(Only Required on Certain Models)

2

The Hubbell Model JTX electric tankless booster heater contains high powered heating elements that heat water only 

when there is demand from the dishmachine.  When hot water is needed, a built in flow sensor measures the exact flow 

rate and that data combined with temperature readings at the heater’s inlet and outlet are processed by the electronic 

temperature controller.  This data is continuously transmitted to the temperature controller, which constantly calculates 

the precise amount of power (kW) needed to achieve the desired temperature.  A zero cross over firing signal is sent to 

the heater's fast acting triacs in order to modulate the heating elements to the precise level needed to meet demand.  The 

Hubbell tankless booster heater uses only as much power as is needed, while delivering accurate and consistent hot water 

temperature.

How It Works

Hubbell Tankless Booster Features

Heater Overview - 3 Element Model Shown

   

By heating water more efficiently... over 98% efficient... and essentially eliminating standby heat  

             loss, the typical owner will save over 2300 KW·HRs per year! Add to that the reduced maintenance 

 

costs of the Hubbell tankless booster compared to a tank type booster and the annual savings easily  

 

add up to over $750 per year.

 

 

 

2300 KW·HRs   x   $0.16 per KWh   =   $368.00 Annual Energy Savings

Tankless Booster Saves Money

       Free up floor space, improve the look and cleanliness of your kitchen, and improve the longevity of  

 

your booster when you mount the Hubbell tankless on the wall.

Space Saving:

Energy Savings:

Note: The Hubbell Model JTX is designed for use with conveyor and flight type dish machines only. This product may not 

operate as expected if the dish machine is other than a conveyor or flight type.

Summary of Contents for JTX011

Page 1: ...gn Engineered specifically for use in commercial kitchens Wide selection of sizes to meet the needs of all dishmachine manufacturers Compact wall mount design saves precious floor space Digital displa...

Page 2: ...the dishmachine When hot water is needed a built in flow sensor measures the exact flow rate and that data combined with temperature readings at the heater s inlet and outlet are processed by the elec...

Page 3: ...perate as a balanced load Tankless Model JTX Standard Specifications Operator Control Capabilities Power Limiting Allows the operator to reduce the power consumption by any percentage to provide insta...

Page 4: ...ection 11 27 KW Models 2 and 3 Element 31 54 KW Models 6 Element Hot Outlet to Dishmachine Warm Inlet Base Model No KW BTU Hr Rating KW Selection 3 Phase Voltages 1 Phase Voltages 208V 240V 480V 600V...

Page 5: ...546 409 273 234 205 164 149 136 117 111 192 42 860 573 430 287 246 215 172 156 143 123 101 51 40 175 48 983 655 491 328 281 246 197 179 164 140 133 116 58 46 230 200 54 1105 737 553 368 316 276 221 2...

Page 6: ...display enclosure can be located up to 250 from the heater and gives the operator full remote control and monitoring capabilities Optional Accessories Example JTX024 3T4 A Hubbell tankless electric bo...

Page 7: ...CS66e 15 24 CL54e CLPS76e CLCS76e 15 27 CL64e CLPS86e CLCS86e 15 27 FT800W FT 900W 24 39 FT 600 FT 700 54 78 FT800 39 78 Opti Rise FT800 36 57 FT 900 36 58 FT800S FT 900S 39 72 NOTE 1 FRC and FR Fast...

Page 8: ...t all times For 3 phase heaters power shall be a 3 wire 3 live 1 ground or a 4 wire 3 live 1 neutral 1 ground system that does not require a neutral leg The heater will draw amps only when operating a...

Reviews: