The output pulse duration (closure) and the DTMF code used for the 

open gate

 command are user 

programmable (see the Output Four Control section). 

TMA can be used to change the contact closure settings if the RED ALERT

®

 telephone is operating in 

SMART mode. 

Hardware Settings

 

Table 2.  Hardware Settings Table 

Function 

Default Settings 

User Settings 

Setting 

Jumper/Position 

Setting 

Jumper/Position 

Auto-answer 

Enabled 

J14/EN 

 

 

Password Protection 

Enabled 

J9/EN 

 

 

Line Polarity 

Non-polarized 

J6/NON 

 

 

Command Select 

Auto 

J20/AUTO 

 

 

DTMF Gain Select 

Low Gain 

J17/LO 

 

 

Low-Power Mode 

Disabled 

J21, J22, J23 not 
installed 

 

 

 

Programming

 

Read this entire section and record the desired key sequences in Table 12 before programming the RED 
ALERT

®

 camera telephone. 

There are two methods to program RED ALERT

®

 emergency telephones; 

Standard Mode 

and 

SMART 

Mode

.  Standard mode programming is used if the telephone system installation does not include TMA 

PC software.  SMART mode programming should be used with TMA installed and the telephones should 
be configured for monitoring.  Normal telephone operation is identical for both modes of operation. 

Each RED ALERT

®

 camera telephone is factory-programmed to receive standard mode commands (see 

Table 12 for the factory-default settings). 

Password Disabled Programming

 

The programmable features of the RED ALERT

®

 camera telephones are protected by a factory default or 

user specified password.  A telephone may need to be configured for password disabled programming if 
the password has been changed from the default and has been forgotten or is unknown. 

To configure a RED ALERT

®

 camera telephone for  password disabled programming: 

1.

 

Access the telephone’s PCBA and disable the password protection feature by moving jumper 

J9

 to 

the 

DIS

 position. 

2.

 

Confirm the auto-answer feature is enabled (jumper 

J14

 must be in the 

EN

 position). 

Summary of Contents for GAI-TRONICS RED ALERT 393-001CAM

Page 1: ...Emergency Call Operation 4 Non Emergency Call Operation 4 Receiving a Call 5 Disconnecting a Call 5 Location Identification 5 Installation 5 Safety Guidelines 6 General Installation Guidelines 6 Locat...

Page 2: ...Sequences 18 Dialing Methods 19 Password Protection 21 Auto Answer Alert 21 Off Hook Ringing 21 Disconnect Options 22 ADA Americans with Disabilities Act Programming 23 Extended Strobe Operation Requ...

Page 3: ...s and report problems when used with TMA Telephone Management Application software Using TMA with RED ALERT telephones reduces system test and maintenance time and decreases liability issues associate...

Page 4: ...vate Automatic Branch Exchange or KSU Key Service Unit NOTE Connection to pay telephone extensions or shared service party lines must be avoided The CCD camera within all RED ALERT camera telephones r...

Page 5: ...package Model 12509 042 includes a single line transceiver for polling a single telephone at a time Each telephone requires approximately 90 seconds to relay its health status to TMA Use multiple tran...

Page 6: ...steadily when the called party acknowledges receiving the call by transmitting a DTMF or after answering the call 2 Two way hands free conversation can now occur Non Emergency Call Operation Applicab...

Page 7: ...oice calls call progress tones i e busy signal fast busy or reorder tone and when enabled dial tone Refer to the Disconnect Options section of this manual for factory defaults and available options Lo...

Page 8: ...in the enclosure supplied with the phone Do not install telephone jacks in wet locations unless the jack is specifically designed for wet locations Do not touch uninsulated telephone wires or terminal...

Page 9: ...ssible Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries to prevent moisture ingress Refer to the exa...

Page 10: ...6 Pull the telephone line through the conduit and into the enclosure 7 Connect the telephone line to the customer supplied telephone line surge suppressor if applicable and modular jack USOC RJ11 or...

Page 11: ...4 467D Camera Telephone Manual Page 9 of 30 P Standard IOMs Current Release 42004 Instr Manuals 42004 467D docx 04 19 Figure 6 Model 394AL 001CAM Figure 7 Model 393 001CAM and 394AL 001CAM Component L...

Page 12: ...e entry hole in the back box 3 Install the telephone line and cable fitting NOTE Telephone line connections directly to terminal block TB1 are acceptable 4 If using the modular jack 1 Remove the cover...

Page 13: ...levels if necessary see Figure 12 for speaker volume and microphone sensitivity potentiometer locations 3 Perform the initial programming see the Programming section 10 Verify operation by calling to...

Page 14: ...shown below Figure 11 Model 398 001CAM is shown as an example Connection to optional GAI Tronics 530 001 540 001 531A Strobe Hardware Configuration The hardware configuration options are explained in...

Page 15: ...f the telephone via polling with SMART operation enabled When the auto answer feature is enabled the telephone automatically answers the call and attempts to communicate with TMA If the caller is not...

Page 16: ...High Gain Selected jumper J17 in position HI Password Enable Disable Factory Setting Password enabled This telephone can be configured to enable or disable the password protection for programming stan...

Page 17: ...ommand if the beep is not initially received NOTE This feature requires the use of GAI Tronics No 40404 045 plug in power supply 120 V ac source required Output four connects to terminal block TB5 on...

Page 18: ...ods to program RED ALERT emergency telephones Standard Mode and SMART Mode Standard mode programming is used if the telephone system installation does not include TMA PC software SMART mode programmin...

Page 19: ...de only the HELP push button Move the switch harness plug from the HELP connector J7 to the CALL push button connector J1 on the telephone PCBA 3 Press the CALL or HELP push button whichever is connec...

Page 20: ...remote access programming Follow these directions to configure the telephone to the desired operating parameters 1 Connect to the telephone locally see the Local Access Programming section or remotely...

Page 21: ...the primary telephone number i e a busy signal or no answer The emergency telephone automatically dials the second rollover number if configured if the emergency call cannot connect to first rollover...

Page 22: ...ce ends in 3 instead of 1 None CALL or ASSISTANCE Button Auto dial DD 4 DD 5 DD 6 Same as HELP Button Auto dial Number 1 except the sequence end digits NOTE The 5 and 6 telephone numbers are used only...

Page 23: ...t password must be supplied to remotely program the telephone If the password has been changed and programming mode can t be accessed see Password Disabled Programming section Example To program the p...

Page 24: ...7 Disconnect Options Feature Key Sequence Description Default HELP Push button Disconnect Option 1 7 L The HELP push button cannot be used to disconnect a call for 10 seconds after initially pressing...

Page 25: ...e enables security personnel to quickly and easily locate an individual in trouble DTMF Call Disconnect Enables the security operator to disconnect the call by pressing Table 8 ADA Programming Feature...

Page 26: ...6 as the control sequence enter 7 2 6 8 90125 Duration of Timed Activation 2 6 N N N Sets the duration of the activation of the Output 4 contact when triggered by the control sequence Use entries 001...

Page 27: ...e activation within 1 second of dial sequence completion No Early Microphone Option Disable 7 1 0 Returns telephone to default operation of microphone Yes SMART Mode Programming TMA software is design...

Page 28: ...wn Operation 1 None Password Protection Feature Programming see Table 4 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 7 Emergency Push button Disconnect 17L 1 enabled Call T...

Page 29: ...performed on a regular basis or when corrosion is first noticed on your Model 397 001CAM or 398 001CAM camera telephone Cleaning For the camera provided inside the telephone periodic cleaning of the c...

Page 30: ...rews Torx T 25 1 inches Pack of 10 12520 009 Push Button Replacement Kit HELP 12520 010 Push Button Replacement Kit CALL ASSISTANCE 12521 004 Microphone Replacement Kit 12522 007 Piezo Speaker Replace...

Page 31: ...l 398 001CAM only chrome plated zinc Dimensions Front panel 12 00 H 10 00 W in 305 254 mm Back box overall 10 06 H 8 43 W 2 50 D in 256 214 63 5 mm Cutout for mounting back box 10 13 H 7 63 W in 257 1...

Page 32: ...The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities o...

Reviews: