Model 397-001ADFS (Flush-Mount Applications)
This compact model telephone is designed for flush-mount installation in openings measuring
7.75 H × 5.75 W inches utilizing a six-hole mounting pattern.
R
Figure 11. Model 397-001ADFS
1.
Remove the back box from the front cover.
N
OTE
:
If mounted outdoors, the installation of a telephone line suppressor (customer-supplied) on the
telephone line is recommended.
2.
Feed the telephone line through either of the cable entry holes in the back box.
N
OTE
:
Telephone line connections directly to TB1 are acceptable.
3.
Connect the telephone’s modular plug into a USOC RJ11 or CA11A (Canada) modular connector or
(if applicable) the telephone line suppressor. An inline coupler is provided for use, if necessary.
Refer to Figure 12 and Figure 13 for mounting details and Figure 15 for component locations.
4.
Reinstall the back box to the front cover.
5.
Allow the telephone a minimum of 35 seconds to initialize.
6.
Using the “Setup” section of this manual,
Configure the hardware as required. Refer to the “Hardware Configuration” section on Page 16
for details.
Adjust the audio levels, if necessary. Refer to Figure 15 for “Speaker Volume” and “Microphone
Sensitivity” potentiometer locations.
Perform the initial programming. Refer to the “Standard Mode Programming” section on Page 21.