Figure 9.  Interconnection Diagram with DC-Powered Strobe 

Maintenance 

Contact a regional service center for a return authorization number (RA#) if the equipment requires 
service.  Equipment must be shipped prepaid to GAI-Tronics with a return authorization number and a 
purchase order number.  Repairs or a replacement will be made in accordance with GAI-Tronics’ 
warranty policy if the equipment is under warranty.  Please include a written explanation of all defects to 
assist our technicians in their troubleshooting efforts. 

Call 800-492-1212 inside the USA or 610-777-1374 outside the USA for help identifying the Regional 
Service Center closest to you. 

Repairing Surface Damage to Powder-Coated Stations 

1.

 

Carefully sand the damaged area to clean and score the base metal, taking care to minimize any 
additional damage to the surrounding powder coating. 

2.

 

Wipe the sanded area with a cleaning solvent, such as DuPont PrepSol

®

 or equivalent.  Allow the area 

to dry.  This type of product is normally available at auto parts stores.  Denatured alcohol may also be 
used. 

3.

 

Prepare the bare metal surface for painting by treating it with a phosphoric acid solution intended for 
this purpose.  The phosphoric acid solution is also normally available at auto parts stores.  Allow the 
area to dry. 

4.

 

Using a cotton-tipped swab or small brush, paint the prepared surface with an automotive enamel or 
oil base polyurethane enamel such as Red Devil, Rustoleum, or equivalent.  Do NOT use Krylon-type 
paints.  Carefully blend the repair enamel into the powder coat at the edges. 

N

OTE

:

  Exact color matches may not be attainable. 

Summary of Contents for GAI-TRONICS RED ALERT 234WM-202

Page 1: ...UCT LITERATURE AND MANUALS Confidentiality Notice 1 General Information 1 Installation 2 No 84505 202 Wall Mount Enclosure Installation 2 Grounding Requirement 3 Tempered Glass Installation Factory In...

Page 2: ...ated emergency communication solution The station accommodates a GAI Tronics Model 39x or 27x Series Flush Mount Telephone and a Model 540 001 or 541 001 Strobe each sold separately The communication...

Page 3: ...ewdriver sold separately is required to remove the tamper resistant screws 2 Remove the wall mounting assembly from the front panel assembly see Figure 1 3 Detach the chain from the wall mounting asse...

Page 4: ...Requirement 1 Ground this unit in accordance with the National Electrical Code NEC in the United States or the Canadian Electrical Code CEC in Canada A 10 grounding stud is located at the base of the...

Page 5: ...ts hold the glass in place 2 Carefully unpack the glass from the box located in the telephone mounting area of the Model 234WM 202 Wall Mount Enclosure 3 Center the front glass left to right and top t...

Page 6: ...ater along with the strobe wires to the incoming power wires in accordance with applicable electrical codes Model 84503 302 Extend the black and the white wires to the base of the station these wires...

Page 7: ...01 Strobe Installation 1 Insert the strobe s 15 foot wires through the station s threaded nipple and allow the wires to extend to the bottom of the station see Figure 6 2 Screw the strobe onto the thr...

Page 8: ...g four 6 32 self tapping flat head screws see Figure 7 The telephone back box has two openings one in the top and one in the bottom 4 Plug the top opening with the hole plug NOTE The bottom of the bac...

Page 9: ...attached to TB1 If the telephone line is to be hard wired to the telephone this cable can be removed and discarded 11 Attach the telephone cable from the surge protector to terminal block TB1 on the t...

Page 10: ...nal Service Center closest to you Repairing Surface Damage to Powder Coated Stations 1 Carefully sand the damaged area to clean and score the base metal taking care to minimize any additional damage t...

Page 11: ...ll material aluminum Finish textured powder coat epoxy Power ratings Model 540 001 AC Strobe 0 39 A 120 V ac Model 541 001 DC Strobe 1 1 A 12 V dc or 0 5 A 24 V dc maximum Model 84503 301 AC Panel Lig...

Page 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: