![Hubbell GAI-TRONICS Clean Phone 295-001F Manual Download Page 18](http://html1.mh-extra.com/html/hubbell/gai-tronics-clean-phone-295-001f/gai-tronics-clean-phone-295-001f_manual_2180597018.webp)
Pub. 42004-484G
Clean Phone
®
Analog Telephones
Page 15 of 26
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-484G.docx
04/19
Standard Mode Programming
Set up each Clean Phone
®
analog telephone locally using
local
access programming or remotely by
calling the telephone from another telephone using
remote
access programming.
Local Access Programming
1.
Press the ON/OFF push button.
2.
Simultaneously press the
1
and
#
keypad buttons after the dial tone is heard from the speaker.
The Clean Phone
®
analog telephone automatically answers the call and generates a splash tone (low
to high sequence), followed approximately by a 1.5-second delay, followed by a success tone (short
beep). The timing sequence to connect to the telephone, authenticate, and enter a programming
sequence is shown below (see Figure 10).
3.
Continue programming the telephone (see the Programming Sequences section).
Remote Access Programming
1.
Enable the auto-answer feature (see the Auto-answer section.)
2.
Use a touch-tone telephone to call the Clean Phone
®
analog telephone.
The emergency telephone automatically answers the call and generates a splash tone (low to high
sequence), followed approximately by a 1.5-second delay, followed by a success tone (short beep).
The timing sequence to connect to the telephone, authenticate, and enter a programming sequence is
shown below (see ).
3.
Continue programming the telephone (see the Programming Sequences section).
TIME (s)
SIGNA
L
(m
V)
SPLASH
TONE
SUCCESS
TONE
DTMF
PASSWORD
DIGITS
SUCCESS
TONE
SUCCESS
TONE
DTMF
PROGRAMMING
SEQUENCE
DIGITS
APPROX
1.5 s
LOW
TONE
HIGH
TONE
Figure 10. Telephone Programming Timing Diagram